Laserfiche WebLink
Jul 09 1� 10: 44a p. l <br /> ITCO ALLIED ENGINEERING COMPANY <br /> AN ALLIANCE OF INSTANT TESTING COMPANY AND ALLIED TEST DRILLING <br /> Jobsrte and Laboratory Testing, Geofechnica/Seryices, Commercial, Residenfia!and Municrpal <br /> 7125 West 126`h Street, Suite 500, Savage, Minnesota 55378 � <br /> Telephone: 952-890-7366 � Fax: 952-890-5883 <br /> July 8, 2010 ' , <br /> Mr. Kevin Shultz Cell: 612-710-4656 <br /> 5620 Girard Avenue North <br /> Brooklyn Center, Minnesota 55430 <br /> RE: 3980 Cherry Avenue <br /> Orono, Hennepin County, Minnesota <br /> As requested, a site visit was made on July 7, 2010 at 10:12 A.M, to evafuate and test soils for <br /> footing placement, at a single-family residence under construction. At the time of the inspection, all <br /> . footings had bee� poured, with the exception �f a 10 foot section at the east end of the south . <br /> footing line. The referenced area had been formed for a standard strip footing, at 21" x 12" and <br /> reinforced with (2) - #4 rods. Soils providing support for the footing line consisted of approximately <br /> 2 '/2 to 3 feet of fine loamy sand engineered fill, underlain by native clay soils. <br /> To assess the strength of the granular fill, a 5/8`h inch diameter smooth probe was used to <br /> penetrate the base of the footing line at randort�. With fulf body weight applied, the probes indicated <br /> penetration, consistent with soils of acceptable consolidation. To evaluate the native soils below <br /> the footing fifl zone, a 1 5/8'h inch diameter fluted hand auger probe was put down at the base of a <br /> sump excavated at the southeast comer of fhe pad. The test was conducted at approximately 4 '/ <br /> feet be{ow'footing elevation, pe�etrating 2 fee�of a stiff, mottled, and cohesive soil. <br /> The load bearing capacity of the engineered fill providing support for the proposed footing was <br /> evaluated with a dynamic cone penetrometer test. The dynamic cone penetrometer (DCP), <br /> employs a eight kilogram (17.6 pound) hammer to drive a 20 millimeter diameter conical point into <br /> the soil, with the penetration recorded in millimeters per blow. From the DCP readings, a per blow, <br /> penetration a�erage was recorcie� and a N-value deriveci. This N-value is an empirical relationship <br /> we have established to equate the dynamic cone data to the more familiar blows per foot (BPF) <br /> standard penetration soil boring test. , <br /> DCP Test —Mid-point of unpoured section (East End South Footing) � <br /> DCP Depth Per Blow Avc�. / N-Value Estimated Load <br /> 469 MM (18.5") 24.6 MM / N-12 3975 PSF <br /> In our opinion, the observed and tested soils are acceptable, and would be expected to meet an <br /> assumed minimum bearing capacity requirement 2000 PSF for the proposed construction. <br /> Our observations and subsequent soi! assessment on this date is limited in scope to soil conditions <br /> for the zone of engineered fill, and subgrade soils within a shallow sump excavation, as evaluated <br />