f � <br /> VentilatiQn, Makeup ana �ompust�on H�r �.a�cu�a��ons <br /> 5ubmittat form for New Dwellings <br /> These biank subm'rttal forms dnd instructions are iveilable at the City of Edina wabsite and st Gry NsIL The completed fnrm rnust be <br /> submittnd in duplicate at the time of applicavon for a met�en(cal permit for new construction.Addiriond Portns m�y ba downtoaded and <br /> prtrrced ar. http://dtYofedina.com/depaRmerrcs/13-09_buildinB.htm <br /> rM CI1b N Ss� '� �� <br /> �k k�rd� �Q �+-� ti�� ���� ` <br /> Section A <br /> Ventilatio�Quar�tity <br /> (cecenrone quancity bv usms reae rnloa.z a equation si-i) <br /> Squere teet�CondiGoned area irxtuding /L 7. <br /> Basemant—ftnished or WMinishetl) �•ti+�` Tatal requ�red veneuetion <br /> Number of bedrooms ! Contfiuous ve�rtilatian <br /> oirections-Determine the tota!and rnntinuaus ventilation ratr 6y either using Tabk N12Q4.2 or equation 11-i. <br /> The table and equatron are below. <br /> Table N1304.2 <br /> Total and Continuous Ventilation Rates(in dm) � S <br /> Number of Bedrooms <br /> 1 2 3 4 5 6 <br /> CondiNoned space(in Total/ Total/ Totsl/ Total/ Total/ Total/ <br /> Sq,{{,) contirluou5 COntinuous GOnti11U045 continuOUS GontinuouS {O�It�nUWs <br /> 10�-15� 60/40 75/40 90/45 105J53 1Z0/GO 135/6B <br /> 1501-20� 70/AO 85/43 100/50 115/58 � 130/65 14S/73 <br /> 2001-2500 80/a0 95/48 110/55 12S/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 k40/7Q 155/78 170/85 185/93 <br /> 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 - <br /> :4501-5000 130/65 14S/73 160/80 175/88 190/9S 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 55�1-6000 150/75 165/83 180/90 195/98 210/ip5 2Z5/113 <br /> E4u�on u-1 15 X S <br /> �0.02 x square feet vf conditloned space)+(15'��bar af bedrooms•1�1�Totai��tton�e�dm) �� ��� <br /> �� , a 4 -�r , ��{ <br /> Tptal ventilation— e mechanical ventilation System shail provide su�oent outdoor air to equal the tatal ventllation rate � �,r- <br /> a�erage,for each one-hour period according to the above table or equadon. for heat recovery ve�tilators�HRV)and energy <br /> recorrery venttlators(ERv)the average hourly ventilation capaaty must be determfned in consideration of any reduction of <br /> exhaust or out outdoor pir intake,or both,for defrost or other equipme�t cycling. <br /> Cpntieuo�vantilation-A minimum of 50 percent of the total ventilation rate,but n�t less than 4Qsim,shall be provlded, <br /> on a continuous rate average for each one-hour per�od. The portion of the mechanical ventilation system intended to be <br /> co�tinuous may have automatic rycling convols providing the average flow�te f�each hour is met. <br /> i�j:aaed 6£0006£�9L�ol :wo.a� }�O�Zt �ti0z-bZ-add <br />