Laserfiche WebLink
, ,ADMINlSTRATION <br /> nection with or concurrently with the work authorized by a in place,but before any plaster is applied,or before wall- <br /> building permit shal]not relieve the applicant or holder of the board joints and fasteners are taped and finished. <br /> permit from fne payment of other fees that are prescribed by R1Q9.1.6 Final i[tspection.Final inspection shall be made <br /> law. after the permitted work is complete and prior to occupancy. <br /> R10S.� Refunds.The buildin�official is authorized to estab- R109.2Inspection ageacies.The building official is authonzed <br /> Iish a refund policy. <br /> to accept report.e of approved agencies,provided such agencies <br /> satisfy the requirements as to quatifications and reliability. <br /> SECf10N R149 R1Q9.3 Inspection requests.lt shall be the duty of the permit <br /> IN!SPcCTl01`"S holder or their agent[o notify the buildino official that such <br /> R109.1 Types of inspections. For onsite construction, from �'ork is ready for inspection.It shall be the duty of the person <br /> time to time the builciing official, upon notification from the requesting any inspections required by this code to provide <br /> permit holder or his agent,shall make or cause to be made any access to and means for inspection of such work. <br /> necessary inspec[ions and shall either approve that portion of R109.4 Approval required. Work shall not be done beyond <br /> the conswction as completed or shail notify the permit holder �e point indicated in each successive inspection witl�out first <br /> or his or her a�ent wherein the same fails to comply with this ��htaining the approval of the buildinb official. The buiiding <br /> code. officiai upon notification,shal]make the requested inspections <br /> R109.1.1 Foundafion inspeetion.Inspection of the foun- and shall either indicate the portion of the construction that is <br /> dation shall be made after po3es or piers are set or trenches or satisfactory as completed, or shall notify the permit holder or <br /> basemenc areas are excavated and any required forms an aaent of the permit holder wherein the same fails to comply <br /> � erected and any required reinforcing stee] is in place and with this code. Any portions that do not comply shall be cor- <br /> supported prior to the placinD of concrete.The foundation rected and such portion shal]not be covered or concealed unu] <br /> inspection shall include excavations for thickened slabs authorized by the building official. <br /> intended for the support of bearinD walls,partitions, struc- <br /> tural supports, or equipment and special requirements for <br /> woodfoundations. SECTION Ri10 <br /> R109.1.?,Piumbinb,mechanical,�as and eiectrical sys- CERTIrICIQ,TE OF OCCt1PANCY <br /> tems inspection.Rough inspection of plumbina,mechani- R110.1 Use and occupanc��.No building or structure shall be <br /> cal, gas and electrical systems shall be made prior to used or occupied, and no change in the existinb occupancy <br /> covering or concealment,before fixtures or appliances are classification of a buildin�or structure or ponion thereof shall <br /> set or installed,and prior to framing inspection. be made until the buildinc official has issued a certificate of <br /> Exception: Back-filling of �round-source heat pump occupancy therefor as provided herein.Issuance of a certificate <br /> loop systems cested in accordance with Section M21 U5.1 of occupancy shall not be construed as an approvai of a viola- <br /> prior to inspection shall be permitted. tion of the provisions of this code or of other ordinances of the <br /> jurisdiction.Certificates presuming to give authority to violate <br /> R109.1.3 Fiooc�plain inspec6ons. For construction in or cancel the provisions of this code or other ordinances of the <br /> areas prone to floodin�as established by Table R3C312(1), jurisdiction shall not be vaiid. <br /> upon placement of the lowesttloor,includinc basemen�_and <br /> prior to fur[her vercical construction, the buildin� official Exceptions: <br /> shall require submission of documentation. prepared and 1. Certificates of occupancy are not required ior work <br /> sealed by a registered design professional,of the elevation exempt from permits under Section R105?. <br /> � of the low�st floor,including basement,required in Section �. Accessor}�bui]dings or structures. <br /> Ri24. <br /> R109.1.4 Frame and masanry inspection. Inspection of Rll�.2 Change in use.Chan�es i.n the character or use of an <br /> framina and masonry construction shall be made after the existing structure shall not be made except as specified in Sec- <br /> roof,masonry, all fratninp,firestoppin�, draftstopping and tions 3406 and 3407 of the International Building Code. <br /> bracing are in place and after the plurnbing.mechanical and g11Q.3 Certificate issued.After the building officia]inspects <br /> elecuical rough inspections are approved. the building or structure and finds na violations of the provi- <br /> Rl(l9.1.� Other inspeetions. In addition co the calied sions of this code or other laws that are enforced be the depart- <br /> inspections above,the building official may make or require ment af buildin� safety, the buildin� ofFicial shall issue a <br /> any other inspections to ascertain compliance with this code ceniFicate of occuPancy which shall contain the following: <br /> and other laws enforced hy the buildin�official. 1. The buildin�perau�number. <br /> R109.2.�.1 Fire-resistance-rated construction �. The address of the structure. <br /> inspectian. Where fire-resistance-rated construction is ;. The name and address of the owner. <br /> required between dwellin� units or due to location on <br /> property,the buildin�official shall require an inspection 4. A descrip�on of that portion of the structure for which <br /> of such construction after all iathin�and/or wallboard is the cenificate is issued. <br /> 6 2006 INTERNtiTIONAL R�SIQENTIAL CODE� <br />