My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-01171 - mechanical
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2805 Casco Point Road - 20-117-23-32-0015
>
Permits/Inspections
>
2010-01171 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:57:57 PM
Creation date
3/16/2016 10:32:21 AM
Metadata
Fields
Template:
x Address Old
House Number
2805
Street Name
Casco Point
Street Type
Road
Address
2805 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723320015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , . <br /> � Heat Loss Subtotal from Pa e 1 S � <br /> SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH <br /> CEIUNG FEET � �' � � � � � � � � � � � � HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> NOINSULATION 18 21 24 27 30 33 36 39 42 45 48 51 54 57 <br /> Fi-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.fi 7.0 7.5 7.9 8.4 <br /> R-19, 6" INSULATION 1.6 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 4.8 5.0 <br /> R30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.8 3.0 3.1 <br /> R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2.2 2.3 2.5 <br /> FLOOR OVER AN SnUAHE DESIGN TEMPERATURE DIFFERENCE gTUH <br /> UNCONDITIONED SPACE FEET � � � � � � � � � � � � � � HEAT LOSS <br /> HEAT TRANSFER MUITIPLiER <br /> NOINSULATION 10 11 13 14 16 17 19 21 22 24 25 27 28 30 <br /> R-11, 3" �NSULATION 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 <br /> R-19, 6"INSULATION t.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4 4,7 4.9 <br /> R-30, t0"fNSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.1 3.3 3.5 <br /> SQUARE DESIGN TEMPERATURE DIFFERENCE gTUH <br /> BASEMENT FLOOR FEET � � � � � � � � � � � � � � NEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> BASEMENT FLOOR 0.8 1.0 1.1 1.3 1.4 1.5 1.7 1.8 2.0 2.1 2.2 2.4 2.5 2.7 � <br /> DESIGN TEMPERATURE DIFFERENCE <br /> CONCRETE SLAB WITHOUT LfNEAR BTUH <br /> PERIMETER SYSTEM FOOT � � � � � � � � � � � � � � HEAT LOSS <br /> HEAT TRANSFER MULTiPtiER <br /> NO EDGE INSULATION 25 29 33 37 41 46 49 53 57 81 fi5 69 73 77 <br /> 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 3l 33 35 37 39 <br /> 2" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8 17.8 18.9 70.0 <br /> CONCRETE SLAB LINEAR QESIGN TEMPERATURE DiFFERENCE gTUH <br /> WITH PERIMETER SYSTEM FOOT � � � � � � � � � � � � � � HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> NO EDGE fNSULATION 57 67 76 68 95 105 114 124 133 143 152 162 171 181 <br /> 1" EDGE INSULATlON 34 40 4& 52 57 63 69 74 80 86 91 97 103 109 <br /> 2" EDGE INSULATION 28 33 37 42 47 51 56 61 65 70 75 79 84 89 <br /> An additional infiftraYiar�load is cafculated anly if the home ia looaely constructed or when windaw infiltration is greater than .5 CFM per <br /> linear foot of c�ack. <br /> ^_ FLOOR SQ FT. x ____.___CEILING HEIGHT = CUBIG F? <br /> i(U FI LTRATIC71111 <br /> VENTELATlON Q•'�x���� �T T � = CFM <br /> MECHANICAI VENT7LC,TlQN CFM1 = FRESH /!IR {NTAKE <br /> � DE&IGN TEMPERATURE dIFFEREIVCE gjUN <br /> CFN� 3Q 35 40 46 SO 56 6L� 66 70 75 80 96 90 � �EAT LOSS <br /> HEAT TRRM14SFEH MUi�TiPItER <br /> INFILTRATIQN � 33 39 4A 50 55 61 6fi 72 l7 83 98 34 99 1U5 � =� <br /> MECHANlCAL VENTILP.TIQN � ' 33 39 44 50 55 61 66 72 77 83 88 34 39 105 - <br /> HEAT LQSS SUBTOTAL <br /> DUCT LOSS BTUN HEAT LOSS <br /> R-4, 1" Flexible Blanket Insulation: ADD 15% 1.151 <br /> R-7, 2" Flexible Blanket Insulation: ADD 10% (.10! <br /> TOTALNEAT LOSS <br /> NOTE: All Heat Transfer Multipliers from ACCA Manuai "J" Sixth Edition. <br /> HL-841-L7 002344 Litho U.S.A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.