SCOPE <br /> DESIGN OF SHALLOW FROST PROTECTION FOR THE EXTERIOR PERIMETER FOOTINGS OF THE EXISTING <br /> REAR STRUCTURE BASED ON THE REQUIREMENTS OF THE IRC AND ASCE 32-01. ALL CONSTRUCTION IS TO <br /> BE IN ACCORDANCE WITH STANDARD INDUSTRY PRACTICE AND THE REQUIREMENTS OF THE CODE. <br /> NOTES <br /> 1. THiS DOCUMENT APPLIES TO FROST PROTECTION REQUIREMENTS ONLY. REFER TO HOME PLAN � <br /> DRAWINGS ALL OTHER INFORMATION. I <br /> 2. DRAIN TILE,DAMPPROOFING AND/OR WATERPROOFING, &FRAMEWALL INSULATION,AS WELL AS THEIR � <br /> INSTALLATION,ARE TO BE IN ACCORDANCE WITH THE CODE. i <br /> 3. INSTALL A MINIMUM OF(2)ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHfN 12"OF i <br /> EACH END. ; <br /> 4. THIS DESIGN CONSTITUTES A COMPONENT REVIEW ONLY. NO OTHER ENGINEERING WAS I <br /> PERFORMED FOR THIS PROJECT. <br /> � <br /> MATERIALS CODES i <br /> 2"RIGID INSULATION: ASTM C578 TYPE IV 2007 MINNESOTA STATE BUILDING CODE i <br /> COMPRESSIVE STRENGTH=25 PSI MIN. w/AMENDED 2006 IRC l <br /> SOIL BEARING CAPACITY:2,000 PSF(ASSUMED) � ASCE 32-01 DESIGN AND CONSTRUCT�ON ,' <br /> OF FROST-PROTECTED SHALLOW i <br /> FOUNDATIONS <br /> HEATED �MPORTANT: I <br /> INSULATED FRAME WALL BY SPACE FLOOR SYSTEM TO HAVE NO � <br /> OTHERS � GREATER THAN R20 � <br /> INSULATION INSTALLED FOR <br /> 6"MIN. CRAWL SPACE TO BE <br /> 12"MAX. CONSIDERED SEMI-HEATED <br /> ! <br /> SLOPE NON-FROST �SEMI-HEATED CRAWL SPACE i <br /> r <br /> SUSCEPTIBLE BACKFILL GRADE GRADE-TO-FLOOR DISTANCE <br /> AWAY FROM FOUNDATION NOT TO EXCEED 24" � <br /> I <br /> ���-,=, �1 I� � - - i <br /> � � III��-,,, <br /> � <br /> 2"RIGID INSULATION � ;' � � � (1)COURSE MASONRY <br /> BLOCK TO BE ADDED TO <br /> EXISTING(3)COURSES <br /> 1'-4" (FULL 8"HEIGHT BLOCKS) I <br /> REINFORCE AS REQUIRED I', <br /> , � I <br /> q ' EXISTING CONCRETE ; <br /> � � °'� � ° STRIP FOOTING � <br /> 2'-8"MIN. <br /> I <br /> I <br /> I <br /> P►OjBCt: I hereby ceMly that tMs plan,apeclflcaHon or report was prepared by Date F;6V ! <br /> Shallow Frost Protection me a under my direct supervlebn and that I nm a dury Ucensad i <br /> 2794 Casco Point Rd Profesalonal Englneer under the lews of the State ot Mnnesota. i <br /> Daro: 4-15-13 Ucense Number. 46665 <br /> Orono, MN , ' <br /> A � /,%I I <br /> t <br /> Ii <br /> C��8�1: Sipned: ���%������ � <br /> Danberry Building Corp P��t Name:_ Nick Hanson '� <br /> 3407 fQlmer Lane NoM i <br /> s�i�a 5413 Manitou Road Project Number: 3.082 ^ J , <br /> Plyrrroulli.MN 55447Td Tonka Ba Drawin Date: Aoril 1 F.2013 V� <br /> B�Z.�oaa�,2 y, MN 55331 9 <br /> www.hansonoroupmn.eom SheSt: 1 Of 1 ' <br /> Q COPYRIGHT HANSON GROUP LLC 2013 i <br /> � <br />