My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00039 - new structure
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2623 Casco Point Road - 20-117-23-24-0032
>
Permits/Inspections
>
2009-00039 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:54:52 PM
Creation date
3/9/2016 3:10:30 PM
Metadata
Fields
Template:
x Address Old
House Number
2623
Street Name
Casco Point
Street Type
Road
Address
2623 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723240032
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� REScheck Software Version 4.2.0 <br /> REScheck Inspection Checklist <br /> Plan Review and Inspection Issues <br /> This list of items may be helpful for Plan Reviewers and Buildi�g Inspectors to use as a guide for enforcing the Minnesota Energy Code.The <br /> items apply to Group R,Division 3 Occupanaes,one-and two-family residential dwellings.The items marked with'appty only to detached <br /> one-and two-family residential dwellings. <br /> Plan Review Issues <br /> Foundation Inspection: <br /> � Foundation wall insulation R-5 minimum. <br /> � Foundation insulation extends from top of wall down to top of the footlng. <br /> 0 E�erior foundation insulation is covered by a protective coating finish. <br /> Concrete Slab or UnderSlab Inspection: <br /> � Slab on grade perimeter insulatron R-5 minimum. <br /> � Slab insulation extends from top of sla6 to design frost line or top of footing. <br /> � Floors over unheated space R-30 minimum. <br /> Windows/Doors/Skylights: <br /> � Average U-value is 0.37 maximum for windows and glass doors(exdudes foundation windows). <br /> � Window U-values consistent with building plan and REScheck Certficate. <br /> 0 Window and door areas consistent with building plan and REScheck Certificate. <br /> Mecha�ical Ventilation Issues: <br /> � Residential mechanical ventilation system provides adequate ventitation per code requirements'. <br /> � Fumace efficiency is consistent with REScheck Certificate or building plan. <br /> � Protection against exoessive depressurization is installed per code requirements'. <br /> Envelope Insulation for Plan Review: <br /> � Interior basement insulation R-5 minimum(if no exterior insulatio�). <br /> � Ceilings with attfcs R-38 minimum or consistent with building plan and REScheck CeRificate. <br /> 0 Wall frami�g and insulation�evel is consistent with buikJing design and REScheck Certificate. <br /> Inspection Issues <br /> Concealed Insulation <br /> Framing and Sheathing: <br /> � Wind wash barrier installed at attic edge. <br /> � Exterior wall comers framed so that insulation can be installed after exterior sheathing is installed. <br /> � Intersections of interior partition walls and exterio�walls framed so that insulation can be installed between the partition and exterior <br /> sheathing after e�erior sheathi�g is installed. <br /> � Gaps between framing less tfian on�half inch are eliminated by securing framing together or are insutated at the time of assembty'. <br /> � All peneVations between conditioned and uncronditioned spaces made prior to framing inspection are sealed'. <br /> Interior Air Bamer: <br /> � All fire stops are air sealed. <br /> � Pipes,ducts,wires,equipment and flues and chimneys through the interior air barrier are sealed. <br /> � A sealed continuous interior air barrier is installed on the wartn side of the building envebpe at ceilings,walls,and floor rim joist areas'. <br /> Project TiUe: Kubalak Home Report date: 12/30/08 <br /> Data filename:C:\Bill-BayCliff Homes,LLC\New BCH-Projects-08\08016-kubalak\Energy-Calcs\kubalak1.rck Page 4 of 5 <br />