My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Wall section specs - hse?garage?
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2618 Casco Point Road - 20-117-23-24-0038
>
Land Use
>
Wall section specs - hse?garage?
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:55:30 PM
Creation date
3/9/2016 1:48:08 PM
Metadata
Fields
Template:
x Address Old
House Number
2618
Street Name
Casco Point
Street Type
Road
Address
2618 Casco Point Road
Document Type
Land Use
PIN
2011723240038
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� IZEWAR.D� <br /> — WALL SYSTEM8 Build Different. Build Better.s"' <br /> �► �° r� <br /> LINIEL MEIGHT 9 iFORM <br /> Design Parameters <br /> Urriel HeigM 8 in. <br /> Co�crete strength at 28 days,tc 3ppp psi <br /> Steel strength,fy 4U.000 psi ,� .______�,,; <br /> , <br /> 1 ; - <br /> 1 : <br /> : <br /> _' .. __. _ .__— - '���� <br /> � ( j � 1 -- � <br /> � • 2 <br /> ;! F�_ r �-- i �.. . <br /> : , ,. � ;'i <br /> , >; � r,. <br /> .�"I �.� �� .. ���.��► _ <br /> _ � ; � � i � � -�J <br /> 1 �: ._ -- _. � , }_. <br /> MINIMUM REINFORCEMENT REQUfRED <br /> FACTOR� <br /> LOAOP6t <br /> FOOTOF Lintel Span (ft) <br /> INTa <br /> __.___ <br /> 3 4 5 6 7 8 10 12 14 18 <br /> �- #5 top and bottom <br /> 250 Ib No Shear ReiMorcement Required !� <br /> 500 ( <br /> i <br /> 750 <br /> 1000 <br /> 1500 <br /> 2000 <br /> 2500 <br /> 3000 <br /> NOTES: <br /> 1. Consult with the local building code for minimum required service loads. <br /> 2. Appiied service loads must be multiplied by load factors to use this table. See ACI 318 or applicable buifding <br /> code for appropriate load factors applied to dead and live loads. <br /> 3. A minimum of 2-#5 bars shall be provided on each side of every opening to meet ACI 318, 14.3.7 <br /> 4. See details in introdudion to IiMel reinforcement for reinforcement placement. <br /> 5. Lintels designed for typical residerrtial construction cases used to establish the vertical reinforcement tables <br /> found elsewhere in this manual may use the following factored loads. Consult an engineer beyond these <br /> parameters. <br /> Factored floor dead and live load=1424 plf <br /> Factored roof dead and live load=1120 plf(no attic); 1800 plf (inGuding attic) <br /> Factored roof dead and snow load=2100 pff (no attic);2780 pff (including attic) <br /> B. #3 stirrups may be substituted where welded wire reinforcement(UVWR)is shown for shear reinforcemerrt. <br /> 7. See accompanying Lint�el Reinforcement Table Notes. <br /> Reward Linte( 6.2.1.1 -9"!8" <br /> Issued on: 4/1/2003 <br /> 6-31 <br /> Release: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.