Laserfiche WebLink
Page 1 Residential Heat Loss and Heat Gain Calculation 5/16/2005 <br /> _ __ _ <br /> In accordance with ACCA Manual J <br /> Report Prepared By: <br /> Milner Mechanical <br /> 4110 Raven Street <br /> New Prague,MN 56071 <br /> 952-758-3495 <br /> For: Eric Vogstrom <br /> 2618 Casco Point Road <br /> orono, MN <br /> ___ _-- - - __ ___ <br /> Design Conditions: Minneapolis/St. Paul <br /> Indoor: Outdoor: <br /> Summer temperature: 75 Summer temperature: 89 <br /> Winter temperature: 70 Winter temperature: -12 <br /> Relative humidity: 55 Summer grains of moisture: 98 <br /> Daily temperature range:Medium <br /> -_ _ _ __ <br /> Building Component Sensible Latent Total Total <br /> Gain Gain Heat Gain Heat Loss <br /> (BTUH) (BTUH) (BTUH) (BTUH) <br /> - ___ - - <br /> Duct 0 0 0 0 <br /> _ -- __ <br /> Floors 0 0 0 1,968 <br /> ___ ---- - ._ <br /> Walls 2,268 0 2,268 19,376 <br /> -- - —-- - --- - <br /> Ceilings 0 0 0 0 <br /> People 1,200 920 2,120 0 <br /> Fireplaces 0 0 0 0 <br /> - - -- _ ___ <br /> Misc 1,200 0 1,200 0 <br /> — __ _-- -- <br /> Windows 15,058 0 15,058 24,970 <br /> Doors 300 0 300 1,402 <br /> Glassdoors 0 0 0 0 <br /> __ _ _ ___ _- - <br /> Skylights 0 0 0 0 <br /> --- - - -- - <br /> Infiltration 1,791 2,135 3,926 15,735 <br /> --- - - - <br /> Whole House 21,817 3,055 24,872 63,451 <br /> ( 2tons ) <br /> - --- __ <br /> HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 <br /> Load calculations are estimates only,actual loads may vary due to weather and construction differences. <br />