Laserfiche WebLink
. , ' <br /> Pernut Number <br /> REScheck Compliance Certi�cate Checked By/Date <br /> 1995 MEC <br /> REScheckSoftware Version 3.5 Release lc <br /> Data filename: C:�Program Files\Check�REScheck�DAD.rck <br /> TITLE: Vogstrom <br /> CITY:Minnetonka <br /> STATE:Minnesota <br /> HDD: 7626 <br /> CONSTRUCTION TYPE: Single Family <br /> DATE: 02/02/OS <br /> DATE OF PLANS: 2/O1/OS <br /> PROJECT 1NFORMATION: <br /> 2618 Casco Point Road <br /> COMPANY INFORMATION: <br /> Vogue Homes,Inc. <br /> COMPLIANCE: Passes <br /> Maximum UA=851 <br /> Your Home UA= 503 <br /> 40.9%Better Than Code(UA) <br /> Gross Glazing <br /> Area or Cavity Cont. or poor <br /> Perimeter R-Value R-Value U-Factor UA <br /> Ceiling 1:Flat Ceiling or Scissor Truss 2510 38.0 0.4 75 <br /> Wall 1: Insulated Concrete Forms 4584 32.0 121 <br /> Window 1: Vinyl Frame:Triple Pane with Low-E 785 0.310 243 <br /> Door 1: Solid 126 0.070 9 <br /> Wa112: Wood Frame, 16"o.c. 950 19.0 21.0 31 <br /> Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 936 38.0 0.0 24 <br /> Furnace 1:Forced Hot Air, 90 AFLTE <br /> Air Conditioner 1:Electric Central Air, 10 SEER <br /> COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, <br /> and other calculations submitted with the pernut application. The proposed building has been designed to meet the 1995 MEC <br /> requirements in REScheckVersion 3.5 Release lc (formerly MECchecl�and to comply with the mandatory requirements listed in <br /> the REScheckInspectio��h�cklist. <br /> � f ; <br /> ,� � . �, � � <br /> Builder/Designer �� � Date <br /> � <br />