My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011166 (mechanical)
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2530 Casco Point Road - 20-117-23-21-0014
>
Permits/Inspections
>
1999-011166 (mechanical)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:51:38 PM
Creation date
3/8/2016 11:05:58 AM
Metadata
Fields
Template:
x Address Old
House Number
2530
Street Name
Casco Point
Street Type
Road
Address
2530 Casco Point Road
Document Type
Permits/Inspections
PIN
2011723210014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Mc. , <br /> ' Ditter, Inc. Chalupsky <br /> Hamel, MN 55340-9691 05-0$-1998 Page 2 <br /> _ __ <br /> _ _ __ __ __ . --_ ___ __ __--__. <br /> Project Summary ' <br /> Project: Chalupsky Company: Ditter Inc. Cooling & Heating <br /> Client: Ted Chalupsky Representative: Doug Bjork <br /> Address: 2530 Casco Point Rd. Address: 820 Tower Drive <br /> City: Orono, MN. City: Hamel, MN. 55343 � <br /> Phone: 471-0802 Phone: 478-9558 � <br /> Fax: Fax: 478-2426 <br /> Comment: <br /> — _ ___ --- <br /> , Design Data <br /> Project Name: Chalupsky <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium I <br /> Latitude: 44 Degrees , <br /> Elevation: 834 Feet ' <br /> Elevation Sensible Adj. Factor: 1.000 I <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference � <br /> Winter. -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 ' <br /> _---- --_- ----- _ _ --- —_.._--- i <br /> Check Figures <br /> Total Building Supply CFM: 1092 CFM per square foot: 0.728 �i <br /> Square feet of room area: 1,500 Square feet per ton: 581.482 II <br /> ---- —_. - -- -- - ---- —_ - - � <br /> Building Loads <br /> Total heating required with outside air: 74,695 Btuh 74.695 MBH <br /> Total sensible gain: 23,836 Btuh 84 % <br /> Total latent gain: 4,482 Btuh 16 % � <br /> Total cooling required with outside air: 28,317 Btuh 2.36 Tons (based on sensible + latent) � <br /> 2.580 Tons (based on 77% sensible capacity) <br /> Notes ---- --- — <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> i <br /> Thursday,December31, 1998 I <br />
The URL can be used to link to this page
Your browser does not support the video tag.