Laserfiche WebLink
f <br /> ♦ ! <br /> S/N 722 RIGHT-J SHORT FORM 7-17-96 <br /> Job # : ' Htg Clg <br /> For: BR.ANDL ANDERSON HOMES Outside db -12 89 <br /> 2490 CASCO POINT RD Inside db 72 75 <br /> Design TD 84 14 <br /> Daily Range - M <br /> Inside Humid. - 50 <br /> By: CONTROLLED AIR HEATING AND AIR CONDITIONING Grains Water - 33 <br /> 21210 EATON AVENUE <br /> FARMINGTON MN 55024 Const . Quality a <br /> 612/460-6022 # of Fireplaces 0 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Make <br /> Model Model <br /> Efpiciency / HSPF 0 . 0 COP/EER/SEER 0 . 0 <br /> Heating Input 0 Btuh Sensible Cooling 0 Btuh <br /> Heating Output 0 Btuh Latent Cooling 0 Btuh <br /> Heating Temp Rise 0 Deg F Total Cooling 0 Btuh <br /> Actual Heating Fan 380 CFM Actual Cooling Fan 380 CFM <br /> Htg Air Flow Factor 0 . 026 CFM/Btuh Clg Air Flow Factor 0 .053 CFM/Btuh <br /> Space Thermostat Load Sensible Heat Ratio 94 <br /> __________________________________________________________________________ <br /> ROOM NAME I SQEFT. I BTUH I BTUH I CFM I CFM <br /> _________________________________________________________________________ __ <br /> 4 SEASON PORCH � 196 � 14402 � 7108 I 380 � 380 <br /> ---------------------------------------------------------------- <br /> Entire House 196 14402 7108 380 380 <br /> Ventilation Air 2310 385 <br /> Eguip. @ 0 . 95 RSM 7119 <br /> Latent Cooling 1002 <br /> _________________________________________________________________________ _ <br /> TOTALS � 196 � 16712 � 8120 � 380 � 380 <br /> MANUAL J: 7th Ed. RIGHT-J: V1 . 74 <br />