[ j all penetrations between conditioned and unconditioned spaces made prior to framing <br /> inspection are sealed * <br /> Interior Air Barrier <br /> [ ] all fire stops are air sealed <br /> [ ] pipes,ducts,wires,equipment and flues and chimneys through the interior air bamer are <br /> sealed <br /> [ ] a sealed continuous interior air barrier is installed on the warm side of the building envelope <br /> at ceilings,walls,and floor rim joist areas * <br /> [ J air barrier behind tub and shower is sealed and protected <br /> [ ] recessed light fixtures are sealed <br /> Envelope Insulation <br /> [ ] basement insulation R-5 minimum <br /> [ ] wind wash barrier on wall separating house and garage is sealed <br /> [ ] loose fill insulation is prevented from entering the eaves <br /> [ ] insulation on skylight shafts and walls exposed in attics is supported on the unconditioned <br /> side <br /> Attic Insulation <br /> [ ] attic access panel insulated to R-38 for ceiling panel and R-19 for wall panel <br /> [ ] attic card attached to framing near access opening <br /> [ ] notification of attic R-value and date of installation posted near building permit <br /> inspection card <br /> This is a summary only. Other requirements may apply. See the Minnesota Energy Code. <br /> Questions? Call the Department of Public Service Information Center at 651-296-5175 or 1-800- <br /> 657-3710. <br />