My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007-P11177 (new structure)
Orono
>
Property Files
>
Street Address
>
C
>
Casco Circle
>
3249 Casco Circle - 20-117-23-43-0008
>
Permits/Inspections
>
2007-P11177 (new structure)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:00:05 PM
Creation date
3/3/2016 12:59:47 PM
Metadata
Fields
Template:
x Address Old
House Number
3249
Street Name
Casco
Street Type
Circle
Address
3249 Casco Circle
Document Type
Permits/Inspections
PIN
2011723430008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exterior insulation has a rigid,opaque,weather-resistant protective covering that covers the exposed(above�rade)insulation and <br /> extends at least 6 in.below grade. <br /> Heating and Cooling Equipment: <br /> ❑ Air Conditioner 1:Electric Central Air: 17 SEER or higher <br /> Make and Model Number: <br /> ❑ Furnace 1:Forced Hot Air:95 AFUE or higher <br /> Make and Model Number: <br /> Air Leakage: <br /> � Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. <br /> � Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from <br /> combustible materials. If non-IC rated,fixtures are installed with a 3"clearance from insulation. <br /> Vapor Retarder: <br /> � Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. <br /> Materials Identification: <br /> � Materials and equipment are installed in accordance with the manufacturer's installation instructions. <br /> � Materials and equipment are identified so that compliance can be determined. <br /> � Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. <br /> � Insulation R-values,glazing U-factors,and heating and cooling equipment efficiency are clearly marked on the building plans or <br /> specifications. <br /> � Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a <br /> manner that achieves the rated R-value without compressing the insulation. <br /> Duct Insulation: <br /> � Ducts in unconditioned spaces are insulated to R-5.Ducts outside the building are insulated to R-8.0. <br /> Duct Construction: <br /> � All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, <br /> or tapes.Tapes and mastics are rated UL 181A or UL 181 B. <br /> Exceptions: <br /> Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). <br /> � The HVAC system provides a means for balancing air and water systems. <br /> Temperature Controls: <br /> � Thermostats exist for each separate HVAC system.A manual or autumatic means to partially restrict or shut off the heating and/or <br /> cooling input to each zone or floor is provided. <br /> Service Water Heating: <br /> � Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat <br /> trap or is part of a circulating system. <br /> � Circulating hot water pipes are insulated to the levels in Table 1. <br /> Circulating Hot Water Systems: <br /> � Circulating hot water pipes are insulated to the levels in Table 1. <br /> Swimming Pools: <br /> � All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable <br /> sources.Pool pumps have a time clock. <br /> Heating and Cooling Piping Insulation: <br /> � HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. <br /> Luesse Residence � � ���� Page 5 of 6� <br />
The URL can be used to link to this page
Your browser does not support the video tag.