Laserfiche WebLink
J't1oN 3�. • • <br /> 9= ICBO Evaluatlon Service Inc. <br /> �P � <br /> iy UWIPOW T � � <br /> � �� � 5360 WORKMAN MILL ROAD • WHITT�R, CALIFORNIA 90601-2299 <br /> ��oa5� A subsidtary corporation of rhe International Conference of Building Officials <br /> n <br /> EVALUATION REPORT . eR-4sss <br /> Copyright m 1997 ICBO Evaluation Service, Inc. Reissued February 1, 1997 <br /> Filing Category: EXTERIOR COATINGS (060) <br /> DRYVIT SPRINT�EXTERIOR INSULATION AND FINISH SYSTEM 2. Wood screws are minimum No.8 corrosion resistant and have <br /> DRYVIT SYSTEMS,INC. sufficient length to penetrate the framing a minimum of 3/4 inch. <br /> ONE ENERGY WAY 2.2.3.3 Masoory: Masonry anchors are No. 10 minimum and are <br /> WEST WARWICK,RHODE ISLAND 02893 corrosion resistant.Minimum 3/g-inch-diameter head with sufficient <br /> 1.0 SUBJECT leogth to penetrate the substrate at least 1 inch is required.Tapco❑ <br /> Dryvit Sprint�Exterior Insulation and Finish System. manufactured by[TW Buildex is a typical masonry anchor. <br /> 2.2.3.4 Light-gage Steel Framing: Screws are minimum No. 8 <br /> 2.0 DESCRIPTION seff-drilling and corrosion resistant with sufficient length to pene- <br /> 2.1 General: trate the framing a minimum of 3/g inch. <br /> The Dryvit Sprint exterior insulation and finish system is a six-com- 2•2•4 Reinforcing liesh:The Dryvit Sprint reinforciag mesh is an <br /> ponent system applied to exterior walls of wood or steel framing, open-weave glass-fiber mesh treated for alkali resistance and weigh- <br /> concrete orconcrete masonry,water-resistant core gypsum sheath- �ng approximately 4.3 ounces per square yard with a 12 by 6 thread <br /> ing board complying with ASTM C 79 and wood-based sheathing count. It is available in 38-inch by 150-foot rolls. Other reinforcing <br /> complying as Exterior or Exposure 1 grade, as noted in NER-108. mesh types such as Standard Plus,Intermediate,Panzer or Corner <br /> The six components coasist of an adhesive, polyisocyanurate Mesh may be used where supplementary impact resistance is <br /> insulation,mechanical fasteners,reiuforcing mesh,a base coat and required,in accordance with the manufacturer's mstructions. <br /> a finish coat. 2.2.5 Base Coat The Dryvit Sprint base coat is available in a dry or <br /> 2.2 Materials: wet mix.The dry mi�is a polymer-modified portland cement plaster <br /> product mixed at the jobsite with water at the rate of one gallon to <br /> 2.2.1 Adhesive: 40 pounds of dry mix to produce the base coat.The wet mix is a fiber- <br /> 1. Dryvit Sprint adhesive is a fully-formulated water-based acrylic reinforced acrylic-based product mixed at the jobsite with Type[or <br /> copolymer that bonds Thermax Quik-R insulation to unpainted II portland cement complying with UBC Standard 17-2 at a ratio of <br /> Exterior or Exposure 1 grade wood-based sheathing,water-re- 1:1 by weig6t to produce the base coat.The dry mix has a shelf life <br /> sistant core gypsum sheathing and unpaiated masonry. The of one year and the wet mi�,two years when stored in a cool dry loca- <br /> adhesive is tinted orange for product identification and has a tion. <br /> shelf life of one year when stored in a cool dry location. 2Z.6 Finish Coat:The Dryvit Sprint finish coat is available in tex- <br /> 2. Dryvit AP adhesive is a moisture-cure urethane constructio❑ ture Types No.100 and No.200.The types are also known as Quarc- <br /> adhesive which may be used in place of the Sprint adhesive.It put2 and Sandblast,respectively.It is 100 percent pure acrylic syn- <br /> has a shelf life of one year when stored in a cool dry location. thetic plaster with the different textures differentiated by aggregate <br /> 2.2.2 lnsulation Board: The insulation board is Thermax Quik-R size and distribution.The�finish coat materials have a shelf life of two <br /> Wall Insulation,a polisocyanurate manufactured by The Celotex Cor- years when stored at 40 F. <br /> poratioa with glass fiber mat facers.The board has a nominal density 2.3 Installation: <br /> of 2.0 pounds per cubic foot and is available in 5/8,3/4, 1, 11/2 and 2.3.1 General: The Dryvit Sprint system may be ad6esively <br /> 2 inch thicknesses. The 5/g- and 3/4-inch-thick boards are for attached or mechanically fas[ened to unpainted wood-based sheath- <br /> application over solid sheathing only.At this density and for a maxi- ing,water-resistant core gypsum sheathing or unpainted masonry. <br /> mum thickness of 2 inches,the board has a tlame-spread rating less The system must be mechanically attached to open wood and steel <br /> than 75 and a smoke-density rating less than 450.The board is avail- stud framing a�d painted masonry. The system is installed only <br /> able in 48 inch widths and 96, 108, 120 or 144 inch lengths. when a wall-surface temperature and ambient temperature of at least <br /> 2.2.3 Mechanical Fasteners: 40°F.can be maintained until the coating has cured.The base coat <br /> must be applied within 14 days after installation of the insulation. <br /> 21.3.1 General:Mechanical fasteners attach the insulation to the <br /> substrate and framiag.Washers are required with all nails,screws Z•3.2 Opea-wood Framing: Attachment to open-wood framing is <br /> and anchors and must be approved by Dryvit Systems,Inc.A plastic limited to maximum 16 inches on cen[er studs.A weather-resistive <br /> Quik-Cap washer supplied by Celotex or ULP-302 plate supplied by barrier complying with Section 1402.1 of the code is applied over the <br /> Wind-Lock Corporation, 13/4 inches in diameter,are two approved studs.The insulation board is then applied over the barrier with the <br /> washers. long dimension vertical and secured to the framing with mechanical <br /> fasteners aod plastic washers described in Section 2.2.3.Spacing of <br /> 2.2.3.2 Wood-based Framing/Substrates: the fasteners is 12 inches on center along the perimeter and in the <br /> 1. Minimum 8d corrosion-resistant ring-shank nails having suffi- field to secure the insulation to the framing. Fasteners must peae- <br /> cient length to penetrate the framing a minimum of 1 inch. trate the framing as described previously.All vertical and horizontal <br /> Evaluation reports ofICBO Evaluation Service,lnc.,are issued solely to provide information to ClassA members of ICBO,utilizjng the code upon which the report <br /> is based.Evaluation reporls are not to be conslrued as representing aesthetics or any other attributes not specifica/ly addressed nor as an endorsement or recommen- <br /> dation for use ojthe subject report. <br /> This report is based upon independent tesfs or other technical data submitted by the applicant.The lCBO Evaluation Service,Inc.,technieal staff has reviewed the <br /> test results and/os other data,but does not possess test jacilities to make an independerit veriftcation.There is no warranty by ICBO Evalaation Service,Inc.,espress <br /> or implied,as to any"Finding"or other matter in the report or as to any product covered by the report.This duclaimer includes,but is not[imited to,merchantability. <br /> ' Page 1 of 6 <br />