RFC 43 <br /> Ordinary Temp. Rating <br /> Max. Coverage Max.Spacing (165°F/74°C) Top of Deflector Minimum <br /> area to Ceiling �nstallation Spacing <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Type Ft(m) <br /> GPM(Vmin) PSI(bar) <br /> 12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) <br /> 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) <br /> Smooth Ceilings%2 to 1(13 to 25.4) <br /> 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) <br /> 13 installed in beams Yz to 1(13 to 25.4) <br /> 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) <br /> 20 x 20(6,1 x 6,1) 20(6,1) 21 (79) 23.8(1,64) <br /> For Ceiling types refer to NFPA 13, 13R or 13D <br /> RFC 49 <br /> Ordinary Temp. Rating To of Deflector Minimum <br /> Max.Coverage Max.Spacing 165°F/74°C p Instailation <br /> area Ft(m) Flow Pressure to Ceiling Type Spacing <br /> Ft x Ft(m x m) GPM Umin PSI bar Inch(mm) Ft(m) <br /> 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) <br /> 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) <br /> Smooth Ceilings Y to 1(13 to 25.4) <br /> 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) <br /> I13 installed in beams'/z to 1(13 to 25.4) <br /> 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12.0(0,83) <br /> 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16J(1,14) <br /> For Ceiling types refer to NFPA 13, 13R or 13D <br /> Maintenance <br /> Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated <br /> klers should be inspected and the sprinkler system Belleville spring washer and machined brass cap water <br /> maintained in accordance with NFPA 25. Do not clean seal assembly containing no plastic parts. Sprinkler K- <br /> sprinklers with soap and water, ammonia or any other factor shall be nominal 3.0(43.2), 4.3 (62), and 4.9(70.6) <br /> cleaning fluids. Remove dust by using a soft brush or having a'�jg , 3�g and �/,6" orifice. Temperature rating <br /> gentle vacuuming. Remove any sprinkler cover plate as- shall be Ordinary 165°F(74°C); cover plate temperature <br /> sembly which has been painted (other than factory ap- rating to be 135°F(57°C). Cover plate assembly shall <br /> plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer <br /> klers should be maintained to allow quick replacement flange allowing a'/z" cover plate adjustment. Any secure <br /> of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will <br /> sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located <br /> and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be <br /> damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup <br /> tion or non-operation. to protect the drop-down sprinkler deflector from dam- <br /> age, which could occur during construction before the <br /> MOdel RFC30, RFC43 and RFC49 Residential cover plate is installed. Standard cover finish: [Chrome] <br /> Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed <br /> sprinklers shall be Reliable Model RFC30, SIN RA0611 <br /> Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) <br /> cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006). <br /> able flat cover plate engineered for a minimum design <br /> density of 0.05 gpm/ft2. Sprinkler frame and deflector <br /> shall be of bronze frame construction having a'/2" NPT <br /> thread. Thermal element shall consist of an approved <br /> black-painted beryllium-nickel fusible solder link with <br /> 3. <br />