Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Pronto Heating and AC � Wyman Addition <br /> Eden Prairie,MN 55344 Pa e 3 <br /> - _ _ _ --� <br /> Total Building Summary Loads _ <br /> Component Area Sen Lat Sen Total <br /> Descri tion Quan Loss Gain Gain Gain <br /> 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), 100 2,838 0 2,119 2,119 <br /> high performance, operable window, e=0.05 on <br /> surface 2, any frame, outdoor insect screen with 50% <br /> coverage, dark color blinds at 45°with 100% <br /> coverage, u-value 0.33, SHGC 0.33 <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 1178.8 6,894 0 2,036 2,036 <br /> cavity, no board insulation, siding finish, wood studs <br /> 16CR-44: Roof/Ceiling-UnderAttic with Insulation on Attic 596 1,128 0 629 629 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic with Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-44 insulation <br /> 22B-10ph: Floor-Slab on grade, Vertical board insulation 64 2,647 0 0 0 <br /> covers slab edge and extends straight down to 3' <br /> below grade, any floor cover, R-10 insulation, <br /> passive, heavy moist soil <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 236 710 0 149 149 <br /> R-30 blanket insulation, any cover <br /> _ _ __- ----- — _ _— <br /> Subtotals for structure: 14,217 0 4,933 4,933 <br /> People: 3 660 900 1,560 <br /> Equipment: 0 300 300 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 63, Summer CFM: 57 5,745 1,147 1,409 2,556 <br /> Ventilation: Winter CFM: 45, Summer CFM: 45 4,130 899 1,105 2,004 <br /> Exhaust: Winter CFM: 100, Summer CFM: 100 <br /> AED Excursion: 0 0 814 814 <br /> - - -- _ - — --__-- _ __-- - <br /> Total Building Load Totals: 24,092 2,706 9,461 12,167 <br /> Check Fi ures <br /> Total Building Supply CFM: 391 CFM Per Square ft.: 0.410 <br /> Square ft. of Room Area: 956 Square ft. Per Ton: 943 <br /> Volume (ft3)of Cond. Space: 8,964 <br /> Buildin Loads <br /> Total Heating Required Including Ventilation Air: 24,092 Btuh 24.092 MBH <br /> Total Sensible Gain: 9,461 Btuh 78 % <br /> Total Latent Gain: 2,706 Btuh 22 % <br /> Total Cooling Required Including Ventilation Air: 12,167 Btuh 1.01 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are perFormed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\Users\UserlDocuments\Elite Software\Rhvac 9 Projects\1 New House.rh9 Friday, October 23, 2015, 2:17 PM <br />