My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00137 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Rd W
>
1185 Ferndale Road West - 02-117-23-43-0025
>
Permits/Inspections
>
2016-00137 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:10:51 PM
Creation date
2/25/2016 10:47:42 AM
Metadata
Fields
Template:
x Address Old
House Number
1185
Street Name
Ferndale
Street Type
Road
Street Direction
West
Address
1185 Ferndale Rd W
Document Type
Permits/Inspections
PIN
0211723430025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Pronto Heating and AC � Wyman Addition <br /> Eden Prairie,MN 55344 Pa e 1 <br /> Project Report <br /> General Pro'ect Information <br /> Project Title: Wyman Addition <br /> Designed By: Doug Dormanen <br /> Project Date: 10-23-15 <br /> Client Name: Kyle Hunt& Partners <br /> Company Name: Pronto Heating &Air Conditioning <br /> Company Representative: Doug Dormanen <br /> Company Phone: 952-835-7777 <br /> Desi n Data <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces North <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference <br /> Winter: -16 -12.38 n/a n/a 70 n/a <br /> Summer: 95 73 36% 50% 72 30 <br /> Check Fi ures <br /> Total Building Supply CFM: 391 CFM Per Square ft.: 0.410 <br /> Square ft. of Room Area: 956 Square ft. Per Ton: 943 <br /> Volume (ft3)of Cond. Space: 8,964 <br /> Buildin Loads � <br /> Total Heating Required Including Ventilation Air: 24,092 Btuh 24.092 MBH <br /> Total Sensible Gain: 9,461 Btuh 78 % <br /> Total Latent Gain: 2,706 Btuh 22 % <br /> Total Cooling Required Including Ventilation Air: 12,167 Btuh 1.01 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\1 New House.rh9 Friday, October 23, 2015, 2:17 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.