Laserfiche WebLink
Wall framing by others <br /> Sill plate by others w/112" <br /> diameter anchor bolts wl 7" <br /> minimum embed&standard <br /> washers @ 72"o.c. max or <br /> Optional slab ledge,maximum � equivalent metal strap anchors <br /> stem height is 12"wl width to <br /> match sill plate \ Grade to be at least 6" below top <br /> �V�3 of wall <br /> • <br /> � (1)#4 continuous horizontal bar <br /> ` w/in 18"of top of wall <br /> i <br /> __ 6" minimum thick cast-in-place <br /> concrete wall <br /> ��r- #4 x 2'-0" long dowels @ 72"o.c. <br /> max wl 5" minimum embed <br /> �...--�'" <br /> �„_. <br /> ,__--- Unreinforced concrete strip <br /> footing per Code by others, <br /> provide frost protection per Code <br /> as required <br /> WALKOUT/ SLAB-ON-GRADE FROST WALL DETAIL <br /> Note: Maximum unbalanced fill height is 36"for 8"thick wall &48"for 10"wall <br /> Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 <,� ` <br /> Project Name: 2015 Standardized Concrete Foundation Drawings Mlnneapolis,MN 55413 �, <br /> Description: Frost Wal�Detail(NOT TO SCALE) Phone:612-720-4639 - <br /> Project# 14.100 Fax:612-886-2966 r <br /> Client Name: Abfalter Brothers Concrete LLC www.oswelleC.Com <br /> Client Address: 15546 Cleveland Street, Elk River,MN 55330 Page S4 of S6 ' <br /> 1124/2015 <br />