Laserfiche WebLink
' c " , <br /> Hickey Consultants Occupational Health and 4301 Spruce Way <br /> Environmental Safety Maple Plain,MN 55359 <br /> 763 479 3214 phone/fax <br /> Hickey Consultants <br /> September 21, 2015 <br /> Sven Gustafson <br /> Stonewood <br /> 153 East Lake Street <br /> Wayzata, MN 55391 <br /> 612-462-4000 Office <br /> 612-267-2670 Cell <br /> S�'E'll LL,'StO1lCWOOa.C011l <br /> Dear Sven, <br /> This letter and attached documentation reports the results of the Asbestos Inspection and Bulk <br /> sampling performed by Hickey Consultants, in the building located at 3185 Casco Circle, Orono, <br /> MN. <br /> This study is significant in that it identifies asbestos-containing materials and provides guidance <br /> regarding the relative location. When a building is to have demolition of structural supports, the <br /> MPCA (Minnesota Pollution Control Agency) requires that the friable asbestos, Freon, PCB and all, <br /> mercury materials be removed prior to demolition of the structure. <br /> SUMMARY <br /> Building inspections, accompanied by bulk sampling of suspect asbestos-containing materials <br /> (ACM), was conducted at 3185 Casco Circle, Orono, MN. Hickey Consultants performed the <br /> inspection. The ACM inspection covered all areas of the building. The building consisted of a 2 <br /> story residential home with a detached garage built in 1905 with a 1648 syuare foot foundation. <br /> No asbestos containing materials were found in the home. Building materials sampled included: <br /> roofing material, tar paper under siding, sheetrock wallboard and joint compound, white spray-on <br /> ceiling material, troweled on ceiling texture, fibrous and mastic like material under the carpet. <br /> Twenty bulk samples were collected and during the building inspection and analyzed for asbestos. <br /> ACM is considered positive with indicating levels of greater than one percent (>1%). The samples <br /> were analyzed and asbestos>1%was not detected in any of the samples. <br /> The thermostats and fluorescent lights must be removed and disposed of properly because of the <br /> mercury concern. The fluorescent light ballasts must be removed because of PCB's concerns. The <br /> refrigerators and air conditioner need to be removed because of Freon concerns. The smoke <br /> detectors need to be removed because of radiation concerns. The city water, electric and gas meters <br /> needs to be disconnected. The microwave, trash compactor, stove, oven, clothes washer and dryer, <br /> water softener, furnace, need to be removed prior to demolition. The extra 12 volt sump pump <br /> batteries in the basement need to be removed because of acid and lead concerns. <br /> 1 <br />