Laserfiche WebLink
i--- --- -- -- —-- <br /> -- -_— — -- ----—-- --- --_ _ _ ---- ---- --- -- -—- — <br /> Rhvac-Residential&Light Commercial HVAC Loads Elite Soflware Development,Inc. <br /> Ferguson Enterprises(Plymout Bill's Heating-770 Brown <br /> Plymouth,MN 55441 _____ - -- Page 2: <br /> — ------- ---- -- --------- <br /> Pro�ect R�ort ----------------------------------- --- ---_ <br /> -_— ---_--- _:_:___---_---------- ------ <br /> - , . <br /> ' Generai Project Information_ ___ ____ '' <br /> Project Title: Bill's Heating-770 Brown <br /> Designed By: Red Owen <br /> Project Date: Tuesday, January 12, 2016 <br /> Client Name: Bill's Heating-770 Brown <br /> Company Name: Bill's Heating-770 Brown <br /> ' Design Data — — -------- �-_— -------�i <br /> Reference City: Minneapolis, Minnesota i <br /> Building Orientation: Front door faces North <br /> ', Daily Temperature Range: Medium <br /> , ', Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor. 1.000 �i <br /> Elevation Heating Adj. Factor. 1.000 <br /> I Elevation Heating Adj. Factor. 1.000 <br /> � <br /> � Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb pifference <br /> Winter: -12 -12.38 80% n/a 70 n/a <br /> Summer: 89 73 47% 50% 75 34 <br /> ------ __-- - -- ----—-- _ ____ ___-------- i <br /> i Check Fi�ures , <br /> ' Total Building Supply CFM: 1,750 CFM Per Square ft.: 0.473 <br /> Square ft. of Room Area: 3,700 Square ft. Per Ton: 1,034 <br /> Volume (ft') of Cond. Space: 33,300 <br /> ---- - — -- -- <br /> ' Building Loads ____ � <br /> Total Heating Required Including Ventilation Air: 86,267 Btuh 86267 MBH <br /> Total Sensible Gain: 37.357 Btuh 87 °i� <br /> Total Latent Gain: 5,563 Btuh 13 % <br /> Total Cooling Required Including Ventilation Air: 42,920 Btuh 3.58 Tons (Based On Sensible + Latent) <br /> ,—_-------- - — — ----- - ------- ---- -__--- <br /> � Notes - -- ---- — ------ <br /> ' Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> ' �;alculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> I All computed results are esttmates as buiiding use and weatner may var� <br /> ' Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data a+ <br /> your design condifion� <br /> i <br /> I <br /> � <br /> I� <br /> I <br /> � <br />