My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00127 - mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Briar Street
>
1380 Briar Street - PID: 10-117-23-31-0053
>
Permits/Inspections
>
2016-00127 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:23:56 PM
Creation date
2/22/2016 10:23:06 AM
Metadata
Fields
Template:
x Address Old
House Number
1380
Street Name
Briar
Street Type
Street
Address
1380 Briar Street
Document Type
Permits/Inspections
PIN
1011723310053
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1322.1104 Minnesota Rule Page 2 of 9 <br /> � I �Z 1 U \ � �L.t,✓ t i/�-Y4 �. <br /> N1104.2.1.1 Ventilation rate. The continuous ventilation system shall be balanced <br /> in accordance with Section N1104.4.2. <br /> Exception: If the local ventilation requirements according to IRC Section R303.3 are being <br /> met by the continuous ventilation system, it shall be capable of operating at a rate not more <br /> than 100 percent greater than required by Section Nl 104.2.1. <br /> N1104.2.2 Intermittent ventilation. The difference between the total ventilation rate <br /> and the continuous ventilation rate shall be based on flow rates as designed or as <br /> installed. <br /> Table N1104.2 <br /> Total and Continuous Ventilation Rates (in cfm) <br /> Number of Bedrooms <br /> 1 2 3 4 5 62 <br /> Conditioned TotaU TotaU Total/ TotaU Total/ Total/ <br /> space' (in Continuous Continuous Continuous Continuous Continuous Continuous <br /> sq. ft.) <br /> 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 <br /> 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 <br /> 2001-2500 80/40 95/48 �110/55 125/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 <br /> 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 <br /> 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 5501-60002 150/75 165/83 180/90 195/98 210/105 225/113 <br /> � Conditioned space includes the basement. <br /> Z If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation 11-1 <br /> from Section Nl 104.2 to calculate total ventilation rate. <br /> N1104.3 Ventilation system requirements. The mechanical ventilation system shall be one <br /> of three types: exhaust according to Section N1104.3.1; balanced, and HRV/ERV according <br /> to Section Nl 104.3.2; or other method according to Section Nl 104.3.3. <br /> N1104.3.1 Exhaust systems. Fans used to comply with the continuous ventilation part <br /> of the mechanical ventilation system shall: <br /> 1. meet the minimum continuous ventilation rate in Section N1104.2.1 at the point of <br /> discharge; <br />
The URL can be used to link to this page
Your browser does not support the video tag.