My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01330 (septic)
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4565 Bayside Road - 06-117-23-21-0010 - New PID
>
Septic
>
2015-01330 (septic)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:24:43 PM
Creation date
2/19/2016 4:11:40 PM
Metadata
Fields
Template:
x Address Old
House Number
4565
Street Name
Bayside
Street Type
Road
Address
4565 Bayside Rd
Document Type
Septic
PIN
0611723210010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-- <br /> � <br /> • .;.:_ OSTP Basic Pump Selection Design <br /> � LINIVERSITY �`'� <br /> Minnesota Pollution Worksheet OF MINNESOTA�i <br /> Controi A enc 't\r' <br /> 1. PUMP CAPACITY Project ID: v 06.12.13 <br /> Pumping to Gravity or Pressure Distribution: �Q c,ravity Q vressure Selection required <br /> 1. If pumping to gravity enter the gatlon per minute of the pump: �GPM (10-45 Spm) <br /> 2. If pumping to a pressurized distribution system: 47.0 GPM <br /> 3. Enter pump description: <br /> 2. HEAD REQUIREMENTS 8�po�nto�lduhi:y`e <br /> A. Etevation Difference �ft m <br /> S���y C�n¢\e�0�h <br /> between pump and point of discharge: <br /> nlel P�V� ElevaUon;•'• <br /> B. Distribution Head Loss: �ft I diHerence <br /> C. Additiondl Hedd Lo55: ��ft(due to special equipment�etc.) ----------------------------- ---•--------- <br /> Table I.Friction Loss in Plastic Pipe per 100ft <br /> Distribution Head Loss Flow Rate Pi e Diameter Iinches) <br /> Gravity Dlstribution = Oft -- --- - - <br /> (GPM) 1 1.25 1.5 2 <br /> _.__. __----- ----- <br /> Pressure D9stribution based on M9nimum Average Head 10 9,1 3,1 1.3 � 0.3 <br /> Value on Pressure Distribution Worksheet: 12 12.8 4.3 1.8 0.4 <br /> Minimum Avera e Head Distributfon Head Loss 14 17.0 5.7 2.4 0.6 <br /> 1ft 5ft �6 21.8 7.3 3.0 0.7 <br /> 2ft 6ft �g 9.1 3.8 0.9 <br /> Sft 1 Oft 20 11.1 4.6 1.1 <br /> 25 16.8 6.9 1.7 <br /> D. 1.Supply Pipe Diameter: 2.0 in 30 23.5 9.7 2.4 <br /> 35 12.9 3.2 <br /> 2. Supply Pipe Length: 70 ft 40 16.5 4.1 <br /> E. Friction Loss in Plastic Pipe per 100ft from Table I: 45 20.5 5.0 <br /> 50 6.1 <br /> Friction Loss= 5.44 ft per 100ft of pipe 55 7.3 <br /> 60 8.6 <br /> F, Determine Equivolent Pipe Length from pump discharge to soil dispersat area discharge 65 10.0 <br /> point. Estimate by adding 25%to supply pipe length for fitting loss. Supply Pipe Length �p 11.4 <br /> (D.2) X 1.25=Equiva(ent Pipe length 75 13.0 <br /> 85 16.4 <br /> 70 ft X 1.25 = 87•5 ft 95 20.1 <br /> G. Calculdte Supply Friction Loss by multiplying Frictron Loss Per 100ft (Line E)by the Equivolent Pipe Length (Line F)and divide by 100. <br /> Supply Friction Loss= <br /> 5.44 ft per 100ft X 87.5 ft - 100 = 4.8 ft <br /> H• Total Heod requirement is the sum of the Elevotion Difference (Line A),the Distribution Head Loss(Line B),Additional Head Loss(Line C),and the <br /> Supply Friction Loss(Line G ) <br /> 8.0 ft + 5A ft + �ft + 4.8 ft = 17.8 ft <br /> 3. PUMP SELECTION <br /> A pump must be selected to deliver at least 4],Q GPM(Line 1 or Line 2)with at least 17,$ feet of total head. <br /> Comments: <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.