My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001-P03940 (new septic)
Orono
>
Property Files
>
Street Address
>
C
>
Carriage Lane
>
2140 Carriage Lane - 10-117-23-24-0035
>
Septic
>
2001-P03940 (new septic)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:22:11 PM
Creation date
2/17/2016 12:43:39 PM
Metadata
Fields
Template:
x Address Old
House Number
2140
Street Name
Carriage
Street Type
Lane
Address
2140 Carriage Lane
Document Type
Septic
PIN
1011723240035
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. i <br /> , <br /> ' Ihzestwood Professional Services, Inc . <br /> I <br /> ��� <br /> ��'�''�'� M �M'�'' <br /> ( .� 104 Marry Drive,Sui�e 3 <br /> �`� _ .�� � � �� Buffalo,MN 55313 <br /> t/YI'4 �� <br /> � Phone:612-682-2587 <br /> ������ Fax 612 687 1639 <br /> ����� Toll Free 1-888 682-2587 <br /> Apri l 21, �999 `������ Email wps�westwoodps com <br /> ��R�11t �r <br /> Steve Bohl <br /> Bohland Development <br /> 420 Upland Lane <br /> Plymouth, MN 55447 <br /> RE: Septic System Site Plan for Lot 4, Carriage Hill, Orono, Minnesota. <br /> Dear Steve: <br /> This proposed on-site septic system was designed for a 5 bedroom home, with an estimated flo�ti c�f 7�0 <br /> �allons per day. The system best suitable for this area �vill be 418 If. of 10" Gravelless trench in�talle� <br /> no deeper than 24" below the existin�� ground level. �t�he seasonal high water table was found at a depth <br /> of 5.0 feet in the septic area. rwo I 300 gallon septic tanks �vill be adequate for a system of this �i�e. <br /> The site in which this system is proposed has an average existing ground slope of 10%. Percolation <br /> rates for this particular site were found to be between 10-16 MPI. <br /> An alternate septic system has been designed to show that there is enough undisturbed area on the lot to <br /> support another septic system. This system was also designed for a 5 bedroom home. The seasonal <br /> water table was also found at a depth of 60 inches, this site would also require 418 If. of I 0" Gravelless <br /> trench. This system will not need to be constructed unless the primary system fails. <br /> Certain precautions will need to be made to protect the areas in which the above referenced septic <br /> systems are proposed. Botl� primary and alternate septic areas have been or will be staked off. It is <br /> recommended that safety fence be placed around both of the sites for protection during construction of <br /> this project. It is critical that the soil is not disturbed before, during, and after construction of the <br /> system. <br /> These system should treat the septic effluent effectively if the systems are installed properly and are <br /> maintained properly. It is recommenced that the septic tanks be pumped once every two years. T�his <br /> will reduce the chance of solids reaching the system. It is also recommended not to use excessive <br /> amounts of chlorine, soaps, and chlorine products which can kill bacteria in the septic tanks. "l�his <br /> bacteria is needed to treat the septic effluent <br /> Designiny the Future ToAay. since 1912 <br />
The URL can be used to link to this page
Your browser does not support the video tag.