My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00040 (new structure)
Orono
>
Property Files
>
Street Address
>
C
>
Carman Street
>
2470 Carman Street - 20-117-23-12-0066 - New PID
>
Permits/Inspections
>
2015-00040 (new structure)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:50:18 PM
Creation date
2/12/2016 2:09:56 PM
Metadata
Fields
Template:
x Address Old
House Number
2470
Street Name
Carman
Street Type
Street
Address
2470 Carman Street
Document Type
Permits/Inspections
PIN
2011723120066
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Rhvac-Residentiaf 8 Light Commercial HVAC Loads Elite Software Development,Inc. ' <br /> Sabre Plumbing&Heating 2470 Carmen St,Jarnes Residence <br /> Plymouth,MN 55447 Page 3 <br /> ' � Miscellaneous Report <br /> System 1 Outdoor �utdoor Outdoor Indoor Indaor Grains <br /> Input Data Dry Bulb Wet Bulb Rei.Hum Rel.Hum Dry Bulb Difference , <br /> Winter: -16 -12.38 100% n/a 70 n/a <br /> � Summer: 90 73 45% 50% 75 31.92 <br /> ! Duct Sizing Inputs _ _---- ._�.. ._T I , <br /> Main Trunk Runouts <br /> � Calculate: Yes Yes <br /> I Use Schedule: Yes Yes , <br /> ! Roughness Factor: 0.00300 0.01000 ', <br /> Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. <br /> Minimum Velocity: 650 ft./min 450 ft./min ' <br /> Maximum Velocity: 900 ft./min 750 ft./min <br /> Minimum Height: 0 in. 0 in. <br /> Maximum Height: 0 in. 0 in. <br /> I Outside Air Data � , <br /> : _ _ _ _ _ __ __- -- __ <br /> Winter Summer i <br /> � Infiltration Specified: 0.100 AC/hr 0.050 AC/hr <br /> , 104 CFM 52 CFM <br /> ! Infiltration Actual: 0.000 AC/hr 0.000 AC/hr <br /> � Above Grade Volume: X 62,667 Cu.ft. X 62,667 Cu.ft. <br /> , 0 Cu.ft./hr 0 Cu.ft./hr , <br /> ' X 0.0167 X 0.0167 , <br /> � Total Building Infiltration: 0 CFM 0 CFM ' <br /> , Total Building Ventilation: 110 CFM 110 CFM <br /> ---System 1--- � <br /> Infiltration&Ventilation Sensible Gain Multiplier: 16.01 = (1.10 X 0.970 X 15.00 Summer Temp. Difference) , <br /> Infiltration &Ventilation Latent Gain Multiplier: 21.06 = (0.68 X 0.970 X 31.92 Grains Difference) � <br /> Infiltration &Ventilation Sensible Loss Multiplier. 91.78 = (1.10 X 0.970 X 86.00 Winter Temp. Difference) , <br /> ' Winter Infiltration Specified: 0.100 AC/hr(104 CFM), Construction: Tight <br /> ; Summer Infiltration Specified: 0.050 AC/hr(52 CFM), Construction: Tight <br /> � <br /> t <br /> � <br /> S:WARNES RESIDENCE Heat Calc.rh9 Tuesday, December 02, 2014, 8:53 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.