Laserfiche WebLink
I <br /> � � `��. <br /> '.\ r �.��R �P�•�s•�r'�'`ttrl <br /> � . w � . '�'��'��. <br /> � DRAWING SCOPE � USE GUtDELINES <br /> SCOPE OF WORK <br /> THESE YEAR 2007 THERMOMASS INSULATED POURED-IN-PLACE (PIP) CONCRETE <br /> FOUNDATION DRAWINGS, CONSISTING OF S-1 THROUGH S-8 AND DATED 2-12-07, ARE <br /> PREPARED BY ULTEIG ENGINEERS, INC. THESE DRAWINGS CONTAIN STRUCTURAL DESIGN <br /> INFORMATION AND DETAILS TO BE USED IN THE CONSTRUCTION OF THERMOMASS <br /> INSULATED POURED-IN-PLACE CONCRETE FOUNDATIONS FOR VARIOUS CONDITIONS <br /> COMMON WITHIN THE RESIDENTIAL MARKET ONLY. THE INFORMATION IS INTENDED FOR <br /> THE CONCRETE CONTRACTOR, AS WELL AS THE GENERAL CONTRACTOR AND THE <br /> FRAMING CONTRACTOR. <br /> THESE DRAWiNGS ARE CERTIFIED AND PREPARED TO THE REQUIREMENTS OF THE <br /> INTERNATIONAL RESIDENTIAL CODE (IRC), AS WELL AS THOSE OF THE MINNESOTA STATE <br /> BUILDING CODES. THESE DRAWINGS ARE VALID THROUGH DECEMBER 31, 2007. <br /> THESE DRAWINGS ARE LICENSED THROUGH AN AGREEMENT BETWEEN ULTEIG AND THE <br /> LICENSEE NOTED IN THE TITLE BLOCK BELOW. THESE DRAWINGS ARE TO BE USED <br /> SOLELY FOR PROJECTS IN WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THESE <br /> DRAWINGS MAY BE RELEASED BY THE LICENSEE TO ITS AGENTS, SUB-CONTRACTORS, <br /> AND CLIENTS FOR THE USE IN PROCUREMENT OF BUILDING PERMITS ONLY. ALL OTHER <br /> USES ARE PROHIBITED. <br /> USE GUIDELINES <br /> FOR EACH PROJECT, THE LICENSEE IS TO INDICATE THE APPLICABLE SHEETS OF THE <br /> DRAWINGS ON THE INDEX SHEET AND THEN SUBMIT THEM WITH THE FULL CONSTRUCTION <br /> DOCUMENT PACKAGE TO THE APPROPRIATE CITY BUILDING DEPARTMENT AT THE TIME OF <br /> PERMIT APPLICATION OR IN ACCORDANCE WITH AN ALTERNATIVE METHOD APPROVED BY <br /> THE CITY. THE CITY BUILDING INSPECTIONS DEPARTMENT WILL REVIEW THE DRAWINGS <br /> AND USE THEM DURING FOUNDATION INSPECTIONS TO ENSURE COMPLIANCE. <br /> THESE DRAWINGS ARE PRIMARILY APPLICABLE TO THE FOLLOWING CONDITIONS: <br /> 1. BASEMENT WALLS TEN FEET OR LESS IN TOTAL HEIGHT <br /> 2. OVERALL BUILDING HEIGNT NOT EXCEEDING TWO STORIES PLUS A BASEMENT <br /> 3. ROOF SPANS NOT EXCEEDING FORTY FEET CLEAR <br /> 4. TOTAI. FLOOR SPANS NOT EXCEEDING FORTY FEET CLEAR <br /> 5. WOOD JOIST, LUMBER, OR TRUSS FLOOR AND ROOF SYSTEMS <br /> 6. CANTILEVERED CONCRETE WALLS NOT EXCEEDING FOUR FEET IN HEIGHT <br /> SPECIAL CONSIDERATION AND DESIGN MAY BE REQUIRED FOR CONDITIONS BEYOND <br /> THESE LIMITS. <br /> 2007 MN MASTER THERMOMASS Thermomass Building Insulation Systems <br /> CONCRETE FOUNDATION DRAWINGS By Composite Technologies Corporation <br /> SCOPE&USE GUIDELINES 1000 Technolagy Drive,P.O.Box 950,Boone,IA 50036 <br /> 5201 East River Road Suite 308 J08 SITE MFORMA710N(to 6e�illed out tly the contractor) Revision Da[e DeScrip6on <br /> Minneapolis,Minnesota 55421 Builder: <br /> PFwne:763.571.2500 Fax:763.571.7166 <br /> Bismarck-Detrou Lakes-fargo�MinneapoYs-Sroux Falls Contraclor: <br /> Web:www.ufleig.com Street Adtlress� <br /> v � ' �� enb�neers DrawnBy:RyanMack Projec[Number: 207.0137 /`�' D <br /> Checked By:Ryan Mack Date: FeDruarv i2.2007 J�� D <br /> Approved By:Craig Oswell Ciry: State:�Zip Code:� Sheets: 2 oi 21 <br /> �c COPYRIGHT ULTEIG ENGINEERS INC.2007 <br />