Laserfiche WebLink
� . <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MICA License#S10 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763)498-8779 Fax(763)498-8290 <br /> September 29. 2002 <br /> L3etz Builders. <br /> 1045 k3rown Road S. <br /> Orono.. Henn.Co. <br /> This on-site Sewage Treatment System is designed for a Type 1, five bedroom home in accordance with the <br /> Minnesota Pollution Control Agency Chapter 7080 and loca(ordinances. <br /> The soils on this site are SCS soils mapped-EnB-Erin Loam.The seasonally saturated soils were loca[ed at 24"-36" <br /> (mottled soil). Due to seasonally saturated soils,a pressurized Mound System will need to be installed to treal septic <br /> ef�luent. T'he bottom of the treatment area must be located at least 3' above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 13 MPI. <br /> All neighboring wells are located geater than 100' away from proposed treatment area. <br /> The existing well will need to be abandoned and a new well installed if the future site is needed. <br /> The existing tank must be abandoned. <br /> The existing building are going to be removed. <br /> A lift pump will need to be installed in the lowest level. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device <br /> must be installed with light and sound devices;this is in case of a pump failure. <br /> "l�he manifold and supply line must have back drainage to the pumping chamber. The distribution pipes shall have <br /> their ends capped. Be sure the rock and sand fill materials are dcan. The sod layer below the entire mounded area <br /> must be turned over,just break up the sod and be sure not to over work. <br /> KeeQ all heavy eauiument off of the proposed treatment areas before during and after constructiou. The area <br /> around both sites must be fenced off by the contractor before any construction begins This DesiQn is oot <br /> valid and the Sy�tem will need to be relocated if failure to nrotect the areas pro�tosed for On-Site Sewaee <br /> Treatment cecurs. <br /> Wi[h proper installation and maintcnance,this s��stem should have no problem in trea[ing septic ellluent eficctivel��. <br /> NMhing other than gray water.(laundry�,showers. etc.) Human ���ater and toilet tissue should be disposed of into thc <br /> septic tanks. Garbage disposals arc not recommended. Additi��es must not be used;they may cause harmful damagc <br /> to your scptic systcm. It is rccommcnded that you pump the tank even�year tbr I tank cvery two ycars tbr Iwo tanks. <br /> Sinctircly, <br /> , �� ����' <br /> _��,��t, .oi��,n � �OROb1V�. ��l�����NfBER <br /> ✓� 0 BF EDROOMS�IYAt,4flA���iEStGN. <br />