Laserfiche WebLink
/_� O �\ <br /> ;'� �. <br /> �:� <br /> ii <br /> /�'O O <br /> ,;�,.. ;; C ITY of ORONO <br /> ,� 5 . � . <br /> i � tS ';� Municipal Offices <br /> ;,,'�+�'�� �: ' ;,�G'� , <br /> Street Address: Mailing Address: <br /> ��ESH��� 2750 Kelley Parkway P.O. Box 66 <br /> __=�� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> �� � <br /> Owner: l���' 1 � � � � Address: 1045 Brown Rd. S. <br /> Permit #'s: 5317 Dates: 9/20/78 Contractors: Jerry Johnson <br /> (This is [x] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 2 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> �} construction, and location. Appears to be operating properly. <br /> UCompliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes ar.d is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is �] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> � Pumpout not needed at this time. <br /> f6, Solids accumulation in tanks indicates they should be pumped out this year. <br /> `7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> , <br /> (The tanks are [ ] or are not [ ] water tight or the condition is ( ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to e ision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: <br /> � � -� �,/ �-- <br /> Da e�of Inspection ep c System Inspect r <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />