Laserfiche WebLink
/, O� <br /> � \ <br /> .;�:" O O '..�� <br /> ;.;�;.. CITY of ORONO <br /> .� � . � <br /> r�`„ � ; �!� ,' Municipal Offices <br /> �� � � G� Street Address: Mailing Address: <br /> �: l� �� � �,�i;% <br /> ��� kEBH�,-�,� 2150 Kelley Parkway P.O. Box 66 <br /> =_ _ = Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> ��. <br /> Owner: � i (' � %t_.:>�;� �-�-��y� C� Addres s: 920 Brown Rd. S. <br /> Permit #'s: 356 Dates: 8/27/63 Contractors: Widmer Bros. <br /> (This is [�� an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all currer.t City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 / Non-Compliant System: System may or may not meet current City standards for design, <br /> �i <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [��] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> 5 Pumpout not needed at this time. <br /> (6 � Solids accumulation in tanks indicates they should be purr,ped out this year. <br /> '�" System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been �umped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> �� One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ �� ] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to be watertight,' this classification is subject to revision.) <br /> �1RAINFIELD CONDITION (11-14) : 11 <br /> /;11 . Drainfield is dry, no surfacing evident. <br /> �2� Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to <br /> public health or safety (surface discharge or backup into the dwelling) . The system must be <br /> repaired or replaced by 12/31/2002 or within ninety days of posing an imminent threat to public <br /> health or safety, whichever comes first. <br /> ,� <br /> ;�� , ,, _ c r� � �� /r��� ; � <br /> Date of Inspection S ic Syst m Inspector • <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />