� Comments: <br /> [ ] � 3. marty's office: Metal Frame with Thermal Break:Triple Pane with Low-E, <br /> � U-factor: 0.310 <br /> � For windows without labeled U-factors,describe features: <br /> � #Panes Frame Type Thermal Break? [ ] Yes [ ] No <br /> � Commen[s: <br /> [ ] � 4. bedroom:Metal Frame with Thermal Break:Triple Pane with Low-E,U-factor: 0.310 <br /> � For windows without labeled U-factors,describe features: <br /> � #Panes Frame Type Thermal Break? [ ] Yes [ ] No <br /> � Comments: <br /> [ ] � 5. exist windows:Metal Frame with Thermal Break:Triple Pane with Low-E, <br /> � U-factor:0310 <br /> � For windows without labeled U-factors,describe features: <br /> � #Panes Frame Type Thermal Break? [ ] Yes [ ] No <br /> � Comments: <br /> � <br /> � Doors: <br /> [ ] � 1. Door 1: Glass,U-factor:0.310 <br /> � Comments: <br /> [ ] � 2• Door 2: Glass,U-factor: 0310 <br /> � Comments: <br /> � <br /> � Floors: <br /> [ ] � 1. Floor 1: Slab-On-Grade:Unheated,6.0'insulation depth, <br /> � R-0.3 continuous insulation <br /> � Comments: <br /> � Slab insulation to exiend down from the top of the slab to at leasi 6.0 ft. OR down ro at <br /> � least the bottom of the slab then horizontally for a total distance of 6.0 ft. <br /> � Exterior insulation must have a rigid,opaque,weather-resistant protective covering that <br /> � covers the exposed(above-grade) insulation and extends at least 6 in. below grade. <br /> [ ] � 2. exist Floor: Slab-On-Grade:Unheated,6.0'insulation depth, <br /> � R-03 continuous insulation <br /> ( Comments: <br /> � Slab insulation to extend down from the top of the slab to at least 6.0 ft. OR down to at <br /> � least the bottom of the slab then horizontally for a total distance of 6.0 ft. <br /> � Exterior insulation must have a rigid,opaque,weather-resistan[protective covering that <br /> � covers the exposed(above-grade)insulation and extends at least 6 in.below grade. <br /> � <br /> � Air Leakage: <br /> [ ] � Joints,penetrations,and all other such openings in the building envelope that are sources of air <br /> � leakage must be sealed. <br /> [ ] � Recessed]ights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly <br /> � with a 0.5" clearance from comb�stible materials.If non-IC rated,the fixture must be installed with a <br /> � 3" clearance from insulation. <br /> � <br /> � Vapor Retarder: <br /> [ ] � Required on the warm-in-winter side of all non-vented framed ceilings, walls,and floors. <br /> � <br /> � Materials Identification: <br /> ( ] � Materials and equipment must be installed in accordance with the manufacturer's installation instructions. <br /> [ ] � Materials and equipment must be identified so that compliance can be determined. <br /> [ ] � Manufacturer manuals for all installed heating and cooling equipment and service water heating <br />