Laserfiche WebLink
/�. O \\ <br /> i/ � � <br /> �,/���/O O\ <br /> �� � ,� �ITY of ORONO <br /> � -. � :,. �, <br /> ��. <br /> ;' z� '�� i. �,,i Municipal Offices <br /> � "� t � ; ti ,. <br /> `�� � ' '�' ``�` �' ��� Street Address qSa'a4q"�6� � Mailing Address: <br /> . l� ; ; ',g,.�, ,', <br /> kESH� 2750 Kelley Parkway P.O. Box 66 <br /> --_' Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �6�� �1�� '�'` �� �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3): � <br /> ( 1 �"CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> �J"COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> whicl�is not failing or an imminent threat to public health or safery. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): .�,� <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this ear (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped S- \0 'C'� ). <br /> Make sure septic tanks are pumped thro�Qh manhole and not through white inspection pipes. This allows for the proper <br /> cleaning Keep water softner and iron filter discharge out of septic system to prolonQ life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is stili workinQ in vour house. The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): �CS <br /> ODrainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �CC�:��:c�� a��� Se�}�,� �.�V�S �oo�� d�. <br /> �,-2.'�--{��-'� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or ceRify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />