My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
420 Brown Road South - PID: 03-117-23-42-0010
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:14 PM
Creation date
2/4/2016 2:43:12 PM
Metadata
Fields
Template:
x Address Old
House Number
420
Street Name
Brown
Street Type
Road
Street Direction
South
Address
420 Brown Rd S
Document Type
Septic
PIN
0311723420010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
= o� <br /> �. � <br /> - o � <br /> ���- o\,,, <br /> � y� C I�Y of ORO�TO <br /> . . � <br /> ,., �:a r,�. � <br /> � '�i' ��„ <,;t,;'� , �, Municipal Offices <br /> i:,�:i�,l.'.., i f.:'y.. 'iA� �� �. <br /> `'�,t � .�<. i;;°�,�,�;, ,� Street Address: q5a-a4q-y6o 0 Mailing Address: <br /> '����p� 2750 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �a`� �J���'"^ Rd� s � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> S STEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM" An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,cksign and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requ'vement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any IS1'S which may r <br /> or may not meet all the location,design,or coasiruction stan�ards of the cuaent Orono Municipal Code and which is failing for any ` <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumP�ed out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped /31-0� ), <br /> Make sure septic tanks are pumaed throu�h manhole and not throu=h white inspection pipes. This allows for the proper <br /> cleaning Keep water softner and iron filter discharEe out of septic svstem to prolon�life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workins in vour house The atarm warns owner that septaEe is about to backup into bas_ement. <br /> 7 Inspection riser.s missing-tanks could not be inspected. Inspection risers(4"dia.pipe}must be mstalled m each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> � Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �o v'�v d' _ _ Se �-,�- �°`�kS I bD�C � . <br /> �_Z-�- a� ��'``�C <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event diat this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properl}. but is mercly an opinion of the adequacy of the system under current <br /> conditions based on the available inlorn�ation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.