Laserfiche WebLink
..j.� �O \` . <br /> �� � <br /> . 0 0�;\ <br /> �'� � � "�� C ITY of ORONO <br /> ,;,t�:;:T�� � <br /> � '��; �, s; `� ,_ �C, , Municipal Off►ces <br /> `C�� ti <br /> ;;.;:?,ti:... ';`,';:, .; <br /> ` '�,t , ;{ .:;�° k?,;�G Street Address: q5a-a�q-�"�60 � Mailing Address: <br /> �X'ESH�¢ 2750 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �3 0 ��04.�. I�d- -S _ <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> STEM CONFORMI'TY (1-3): � <br /> 1 "CODE SYS'I'EM" An IST'S which meets all the location,c�sign and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standazds of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. <br /> 3 "NON-COMPLIA.NT SYSTEM" A prohibited ISTS;an ISTS located within a designated]00-year flood plain,any ISTS wluch may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsarivated soil or sand between the distribudon device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleaning Keep water softner and iron filter dischar�e out of septic svstem to prolont life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workins in vour house The alarm warns owner that septaee is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three yeazs,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �Co�;c.���.I� I�OKS ��� IT v�-� S-���;L j�� _ <br /> S�c:c�, 2..-0OS - <br /> �� <br /> 6-Z�-vy �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event d�at this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that tl�is report dots <br /> not guaranlee or certify that an esisting system �vill continue to function properly. but is mercly an opinion of the adequacy of the system under current <br /> condi[ions based on the available ini'om�ation. <br />