My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
440 Brown Road South - PID: 03-117-23-42-0012
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:21 PM
Creation date
2/4/2016 1:54:50 PM
Metadata
Fields
Template:
x Address Old
House Number
440
Street Name
Brown
Street Type
Road
Street Direction
South
Address
440 Brown Rd S
Document Type
Septic
PIN
0311723420012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� - -0�� <br /> �. 1V' <br /> ; O O�, <br /> � ���'� ciTYof o�co�o <br /> :: <br /> ,, �:: , � <br /> �ar:�. � <br /> � <br /> � �;�,� } <br /> � ��j�,'� ,;,F.` , ��, Municipal Offices <br /> ` '���� � r fr' �;t;'�G Street Address: �15a'a�q—�"16� � Mailing Address: <br /> •9xEs�p'� 2750 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: <br /> �f4� Q���.,,, Rd . s � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMTTY (1-31: � <br /> 1� "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the ttuee foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an iccnninent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than thcee feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �' <br /> Tank inspection indicates: <br /> �5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped )• <br /> Make sure septic tanks are pumped throu�h manhote and not through white inspection pipes. This allows for the proper <br /> cleanin8 Keep water softner and iron filter discharge out of septic svstem to prolong I�fe of dra�nfield. Ask pumper to test <br /> alarm float to verifv alarm is still workinQ in your house The alarm warns owner that septage is about to backup mto basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the Surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> �- SC }-�Z �c.n� \6�� �� - <br /> COMMENTS: Mo v�� P - <br /> (� �ti.'�- a y v'"'`a; <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: ln the event that this inspection report is used to satisfy the requirements for a mortgage or other transf'er of property, be advised that d�is report does <br /> not guarantee or ceitify that an existing system �vill continue tu function properly. but is mercly an opinion of the adequacy of the system under current <br /> conditions based on the available intorniation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.