Laserfiche WebLink
. Y` � �Y � <br /> , � �1'-1�i <br /> ; - , �il���►� ����� <br /> �a '�;°~r:�;,. � <br /> v�;,� ��;�,,J, 'it;, , !4 Municipai �t'tices <br /> ::�.- : �. � '�v <br /> ,L � �;." `,':��G Street Address: `��a-a��-y�a C' MalUag Rddress: <br /> `$�C'E��O�' 2750 V(elley Parkway PA. Box fi6 <br /> - Orono, MN 55356 Crystal Bay, MN 553Z3•0066 <br /> To Current Owner: Address: -T4� ���``�^ �� - s' <br /> City Ordinance 199 requires that eacl�existing on-site sew�tge treaUnent system in Orono be inspected every iwo years. <br /> The on-site sewagc treatment system at the abave acldress has been inspected and appears to fal I irtto the categories checked below. <br /> SYSTEM CONC�RM[TY fi-3): � ' <br /> 1 "CODE SYST'ER4"An IS7'S whieh meets al!the loeation,design and coastntction standards of the currcnt Orono Municipal Code. <br /> 2 "COMPLIAATT SYSTEM" An fSTS which does not mezt ell tlse locazion,design and construction standards of thc current Oroito ' <br /> Municipal Cude but does meet tlie thmz foot se�ara[ion requiremenc ar nvo foot requirement for systems installed 1996 or earlier,aud <br /> ��� which iS no[fitiling or ap inmiinzni threat to pu6lic hea3th or safeh�. <br /> ( 3 / "2�'OiV-COIviFLTANT SYS"f�M" A prohibited 157'S;an ISTS located wiihin a designatcd 100-year flood p3nin,any ISTS which may ' <br /> `•� or may not meei ail tlie loca[ion,design,or coastruetion stant�rds of�c curreni Orono Manicipal Cade artd which is failing for any <br /> reason,and any ISTS 4vfth less than tivce feet of unsnmratod soil ar sand bet�veen the distribution device a�d the liFuiting soil characteristics. ' <br /> �rArrrc corm��orr rs-��: �� <br /> Tnnk inspecfion indicates, <br /> � Pumpout not needed at this time. ' <br /> 6 5eptic tanlcs must be pumpe�out thes year (city code recommends tanks to be pumped out once every 3 years. ' <br /> Tanlc was last pumped C1—11�0�� ). ', <br /> htake sure seRYic tanks are pumped throueh manhole and not throuah white insnection pipes. This allotivs for the prancr ' <br /> cleanin�. ICeep water softner and iron filter disch�r�e out of sePtic svstem to prolong Iife of drainfield. Ask pumper fo test ' <br /> alarm float to verifv a[arni is sti31 workirce in vour house. The al:trm warns owr+er thai septaQe is about to backun into basemerct. ' <br /> 7 Inspection risers missing-tanks coutd not be inspected. Inspection risers(4"dia.pipe)musE be instailed in each tank. If ' <br /> taaks have not been pumped out within the last ihree years,they should 6e puraped out now. ' <br /> D TFIELD CONDI'tI0I3 6-1 U': d <br /> S Drainfield is dry,na surfacing evideui. <br /> 9 Some evidence af surfacing,not critical yeL ' <br /> 10 Drainfieid is saiurflted and visibly discharging untreated effluent to the surfa�e, Contact the City Inspector <br /> immediaiely.Repairs must be completed within 90 days. <br /> co�MENTs: ac�.��;et� ,s ���_ co�p,���- �- r�,U�-- b� <br /> �'C�1\nc��} �� 11-"3� - `LD� o . ' <br /> b-Z-�—0� �� ��.� ���� <br /> Date of lnspection Matt Boltcrman - 5eptic Systen�inspecco; <br /> �ote: lo tl�e cvent tha� Ihis inspection report is used to satlsfy the requiren}ents for a morteaez or oi3ier transier of propem•,be advised that lliis report docs <br /> nut guarenice or eertif)' that an existing syseenz a�ill eontinuc tv function properi}. oul ia mcrd� an opinion of thc adequaey of the sysiem undcr curreni ; <br /> cunditiuns based on the available informTtion <br />