Laserfiche WebLink
� �+ SEPTIC SYSTEM INVENTOR Y <br /> _ _ _ _ _ _ __ _ <br /> Address: 265 Brown Rd. S. PID: 03-1 17-23 24 0001 � <br /> Building Typ residence #BRs/GPD: 4 #Systems 1 Units Billed 1 <br /> Permit#: 206, 514 Date of Permit: 9/21/87, 5/19/ Installer: Halstad Contr., Coolbrot <br /> System Type standard trench Experimental: no Appliances lndry <br /> SYSTEM CONDITION <br /> Conformity: 3 Tank Condition: 5 DF condition: 11 Failure Pot: med <br /> � <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000 <br /> Setback to Bldg: 14 Cesspool: no <br /> DRAINFIELD <br /> � <br /> Length of Lines 225 # Lines: 3 Trench Width: 3 e <br /> Treatment Area: 675 Type of Filter rock Soil Boring: yes <br /> Tile Size: 4 Under Tile 12 Perc Rate: 15 <br /> Setback DF-Bldg: 40 DF Ht above Wt: 1.4 <br /> Soil Type: loam, clay loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File no <br /> Pump Type: Depth: Diameter: Method: <br /> INSPECTION RECORD PUMPOUT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 5/1/82 me w/Ed Sullivan on site RE: repairs 6/4/84 1000 <br /> 8/12/82 system is dry for now 3 6/8/87 500 <br /> 6/19/86 slight seepage, not critical yet 3 <br /> 7/29/86 still seeping 3 <br /> 9/23/87 new system installed 1 <br /> 10/10/90 no surfacing-pump tanks 1 <br /> 5/26/92 no surfacing-pump tanks 1 <br /> 9/28/95 no surfacing 1 <br /> 10/12/98 non-compliant-slight surfacing,repair 200 3 <br /> 9/18/00 non-compliant, connect to sewer 2010 3 <br /> � , �-� �Q.�,,��2 �n c 1 � o 0 <br /> C� c�v1 PCi� <br /> ._ .�� ��wc:� ��► S�c�� f;le . <br /> / <br /> . �� <br />