Laserfiche WebLink
� \ <br /> �• � _ : _. <br /> 1� O O`\\`, <br /> �� � � CITY of OIZOl\TO <br /> , .;,:r,:�. <br /> ,� 1� .� � <br /> ,,; . <br /> '�'.� �' �� d) ��. ,�ti ' Municipal Offices <br /> t9 ' ' �tig.�,G Street Address: �lSa-d49-y6o � Mailing Address: <br /> �ESH� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: I �� �J��""^ 0�-� S , <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): I <br /> (1 / "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> v <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or rivo foot requuement for systems instafled 1996 or eazlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stanc�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure seatic tanks are pumped throu2h manhole and not throush white inspection aipes This allows for the proper <br /> cleaninQ. Keep water softner and iron filter discharae out of septic svstem to prolone life of drainfield Ask pomper to test <br /> alarm float to verifv alarm is still working in vour house. The alarm warns owner that septaQe is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : d <br /> Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not criticat yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: i�� ``����e�d �ob�CS �� � P���. .: S(� �-L ���I <br /> S��-�-�� Z�O� <br /> �-1b-e� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property. be advised that this report do�s <br /> nut euarantee or certif� that an existing svstem �vill continue to fiuiction properl�. but is merely an opinion of the adequacy of the s�stem under current <br /> ronditions bascd on the availablc inlonnation. <br />