Laserfiche WebLink
- - -01�� � <br /> �. �' �, . _ . <br /> ;-; O O �, <br /> ,�, <br /> �-� - <br /> � '' CITY of O►RONO <br /> ,; . <br /> ,,,}::r�� <br /> .� " . ��� _ � <br /> �, �,.� <br /> � .�r�',, '�f' �• '��G:'', ,. �ti Municipal Offices <br /> '�t;;�,,�,,.:; '1 �:;..,,�ti}�G <br /> Street Address: �15a-a4q-ybo O Mailing Address: <br /> '`��'E�gOg' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: 1 �� ����"'^ �U� � - <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and conswction standards of the current Orono Municipal Code: <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requ'uement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIAN'T SYS`I'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Ta k inspection indicates: <br /> 5 1 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not throueh white inspection pipes. This allows for the proper <br /> cleaninQ. Keep water softner and iron filter discharEe out of septic svstem to prolonQ life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workin�in vour house. The alarm warns owner that septaEe is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: I����� �- S�� �:� _ �--�;�tt� - ,_. ._`o a�� �l� <br /> f� <br /> p��� �-�...1c s S v n..+�-{� 200 5'. <br /> �-16- v ti �� <br /> � <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the e��ent[hat this inspection report is used to satisfy the requirements for a mortgage or o[her transfer of propertv, be advised that this reE�ort does <br /> nut �uarantee or certify that an existing system �vill continue to function properly. but is merely an opinion of the adequacy of thz s}stem under current <br /> ronditio�i;based on the a��ailable inlonnation. <br />