Laserfiche WebLink
;:--0�\� <br /> 7 � ��� <br /> � � �1`, <br /> � ��� � ��� CITY of ORONO <br /> .� :f:�, _ � . <br /> �,,;' Municipal Offices <br /> � '�'+�'� � :~ _ �'ti i� <br /> � {`� Street Address: Mailing Address: <br /> ����`9JfE8Kpj�� 2750 Kelley Parkway P.O. Box 66 <br /> �_� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> 1 � !! i <br /> Owner: 1.,�...1Q (7"�{� ����i ����7// � �✓ ' Addres s: 130 Brown Rd. S. <br /> Permit #'s: 4977 Dates: 10/12/77 Contractors: Widmer Bros. <br /> (This is [�] an existing system ( ] r.ew construction) . <br /> SYSTEM COMPLIANCE (1-3) : �3`) <br /> 1 Code System: Meets -6r exceeds cu-rent City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> /3�, Non-Compliant System: System may or may not meet current City standards for design, <br /> L•- construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [X ] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : (9; <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates tney should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> -, within three years, they should be pumped out and risers installed now. <br /> �9 ; Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> ,BF�IINFIELD CONDITION (11-14) : lj <br /> �11� Drainfield is dry, no sur cing evident. <br /> T� Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discnarging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Reoair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTEr�TIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to <br /> public health or safety (surface discharge or backup into the dwelling) . The system must be <br /> repaired or replaced by 12/31/2005 or within ninety days of posing an imminent threat to public <br /> health or safety, whichever comes first. ,, <br /> l��' <br /> ,�� � _2 - y`�� ;l' r�-- <br /> Date of Inspection Sept�c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the ope�ation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />