Laserfiche WebLink
j.� o � <br /> � � <br /> • '', '�O o�\1`l�l <br /> �� y � CITY of OItONO <br /> ,�.��.r,� ,Y, <br /> � � . �,} <br /> � '�j? � ,;,k; `` � Municipal Offices <br /> '��„ "� ,E' ` t�il�G~ Street Address: q5a-a4q-y6o O Mailing Address: <br /> 9��xp4� 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: <br /> Address: � 3� ��a�^ ' �" - S " <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. ____ <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an inuninent threat to public health or safety. <br /> ( 3 � "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> �J or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> O6 Septic tanks must be pumped out this ear (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 11��`5� )• <br /> Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This allows for the proper <br /> cleaning Keep water softner and iron filter dischar�e out of septic sYstem to prolonQ I�fe of dramfield. Ask pumper to test <br /> alarm float to verify alarm is still workinS in your house The alarm warns owner that septage�s about to backup mto basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"d�a.pipe)must be mstalled m each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : ,� <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> - ���:.��-:�.�� �s ro.,_ ca.- ��.�- a- h�1�- �C r� ►au� <br /> COMMENTS: <br /> �,� �t=�� 2oio ��-p Sc��;� �-�,�k'� Spc,�..` �-oos. <br /> _ —�-- <br /> 6-16-o�k G��- <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event diat this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that diis report does <br /> not gu�rantee or certify that an existing system will continue to fimction properly. but is merely an opinion of the adequacy of the system under ciirrent <br /> eonditions based on the available intonnation. <br />