Laserfiche WebLink
:-o_,,�, <br /> � � � �., <br /> 0 0� <br /> ;:�.. CITY of ORONO <br /> � � <br /> !�;���� Municipal Offices <br /> "�+�� -,, ��' � <br /> .� ��` � ,�' Street Address: Mailing Address: <br /> � 9$EggOg'�� 2750 Kelley Parkway P.O. Box 66 <br /> _-_=" Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � ' _ <br /> � � <br /> Owner: ` 1 j�� Address: 25 Brown Rd. S. <br /> Permit #'s: none Dates: Contractors: unknown <br /> (This is [�] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> \3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level is [�,] or is not [ ] identifiad under this septic system. If the <br /> saturatad soil level is not id'entified, this classification is subjact to revision.) <br /> TANK CONDITION (5-9) : 8 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> r8� Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> �� within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is �] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 11 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0.5 feet and the system is non-compliant. Repair or replacement of <br /> the septic system is required by 12/31/2008. <br /> I <br /> ��--/q� �----_ <br /> Date of Inspection Sep i System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />