My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1998-010997- mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road North
>
1060 Brown Road North - 27-118-23-42-0005
>
Permits/Insepections
>
1998-010997- mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:01 PM
Creation date
1/28/2016 2:41:56 PM
Metadata
Fields
Template:
x Address Old
House Number
1060
Street Name
Brown
Street Type
Road
Street Direction
North
Address
1060 Brown Road North
PIN
2711823420005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Heat Loss Subtotal from Page 1 � �J <br /> DESIGN TEMPERATURE DIFFERENCE <br /> CEILING S�EETRE � � � � � � � � �� 75 � � � � HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> NO I N S U LATION 18 21 24 27 30 33 36 39 42 45 48 51 54 57 <br /> R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.6 7.0 7.5 7.9 8.4 <br /> R-19, 6" INSULATION 1.6 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 4.8 5.0 <br /> R-30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.8 3.1 <br /> R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2. 2.3 2.5 <br /> DESIGN TEMPERATURE DIFFERENCE <br /> FLOOR OVER AN SQUARE � � � � � � � � 70 � � � � � BTUH <br /> UNCONDITIONED SPACE FEET HEAT TRANSFER MULTIPLIER HEAT LOSS <br /> NOINSULATION 10 11 13 14 16 17 19 21 22 24 25 27 30 <br /> R-11, 3" INSULATION 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7. 7.6 � <br /> � R-19, 6"INSULATION 1.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4 4.7 4.9 <br /> R-30, 10"INSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.1 3.3 3.5 <br /> DESIGN TEMPERATURE DIFFERENCE <br /> BASEMENT FLOOR SaEETRE � � � � � � � � �� � � � � � HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> BASEMENT FLOOR 0.8 1.0 1.1 1.3 1.4 1.5 1.7 1.8 2.0 2.1 2.2 2.4 2.7 <br /> DESIGN TEMPERATURE DIFFERENCE <br /> CONCRETE SLAB WITHOUT LINEAR BTUH <br /> PERIMETER SYSTEM FOOT � � � � � � � � �0 75 80 �i 90 95 HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> NO EDGE INSULATION 25 29 33 37 41 45 49 53 57 61 65 69 73 77 <br /> 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 31 33 35 37 39 <br /> 2" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8 17.8 18.9 20.0 <br /> DESIGN TEMPERATURE DIFFERENCE <br /> CONCRETE SLAB LINEAR � � � � � � � � �� 75 � � � � BTUH <br /> WITH PERIMETER SYSTEM FOOT HEAT TRANSFER MULTIPLIER HEAT LOSS <br /> NO EDGE INSULATION 57 67 76 86 95 105 114 124 133 143 152 162 171 181 <br /> 1" EDGE INSULATION 34 40 46 52 57 63 69 74 80 86 91 97 103 109 <br /> 2" EDGE INSULATION 28 33 37 42 47 51 56 61 65 70 75 79 84 89 <br /> An additional infiltration load is calculated only if the home is loosely constructed or when window infiltration is greater than .5 CFM per <br /> linear foot of crack. <br /> FLOOR SQ Ff. x CEILING HEIGHT = CUBIC Ff <br /> INFILTRATION/ <br /> VENTILATION 0.40 x CUBIC Ff = 60 = CFM <br /> MECHANICAL VENTILATION CFM = FRESH AIR INTAKE <br /> DESIGN TEMPERATURE DIFFERENCE BTUH <br /> CFM 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT LOSS <br /> HEAT TRANSFER MULTIPLIER <br /> INFILTRATION 33 39 44 50 55 61 66 72 77 83 88 94 105 <br /> MECHANICAL VENTILATION 33 39 44 50 55 61 66 72 77 83 88 94 9 105 <br /> HEATLOSS SUBTOTAL <br /> DUCT LOSS BTUH HEAT LOSS <br /> R-4, 1" Flexible Blanket Insulation: ADD 15% (.15) <br /> R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) <br /> TOTAL HEATLOSS <br /> NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition. <br /> HL-841-L7 (14G48) Litho U.S.A. <br />