Laserfiche WebLink
j.� �O � <br /> �� � <br /> . 0 ��'`, <br /> ��� -:� _ ''� CITY o� �R�lOTO <br /> ,,,�:�,�� <br /> � '�i;ti�. %;,'G;} ,. ��, , Municipal Offices <br /> � ;.;,,,�:. ';' :, .; <br /> � ��- ;;" '��;1�' G SVeet Address: qSa'a4q"y6� � Mailing Address: <br /> �`4�j' � p4'� 2750 Kelley Parkway P.O. Box 66 <br /> E$8 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �a5 'J r0�"''� � � �' <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�9nent threat to public health or safety. <br /> � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an IST'S located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standazds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribudon device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): SS <br /> Tank inspection indicates: <br /> � Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped `'��ro� ). <br /> Nlake sure septic tanks are pumped throuQh manhole and not through white inspection pipes. This allows for the proper <br /> cleaninS Keep water softner and iron filter discharse out of septic svstem to prolonE life of drainfield. Ask pumper to test <br /> alarm float to verifv atarm is still workinE in your house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION(8-10): ,�, <br /> � Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated ef�luent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> NTS: DCa;�—�-:c\t� �S c�e�— (o., ��h,.�— � r��Z bC Ct �atcJ <br /> C�MME <br /> 1,-.( �L 71 —Zoc��_ <br /> �-\��-�� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event diat this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not �uarantee or ceRify that an existing system will continue to function properly. but is merely an opinion of the adequacy of the system �mder current <br /> �_ —-`---�_._.�.....,..:�..�.ie:.,r.._....;,.., <br />