Laserfiche WebLink
,_ __ _—, <br /> �%' � � <br /> ��, <br /> � �� � � <br /> O O <br /> . r�,._ ,� CITY of ORONO <br /> � , <br /> r �r, Municipal Offices <br /> '� �,� �ti,,, <br /> �� �� �. .����.� /� Street Address: Mailing Address: <br /> $EggO� 2750 Kelley Parkway P.O. Box 66 <br /> --- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: ���� �-�I�� Address: 915 Brown Rd. N. <br /> Permit #'s: 30 Dates: 10/15/53 Contractors: owner <br /> (This is [�] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [,x] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (S-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been p�mped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is �] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 14 <br /> 11 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 4 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: The septic system is non-compliant and must be connected to municipal sewer by <br /> 12/31/1998. <br /> ���9� �,� �� , ��-- <br /> Date of Inspection S tic System Inspec or <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />