Laserfiche WebLink
j.� �O \ <br /> � � <br /> . ���O O�\��'1`� <br /> " ;i;l AR�r�. �'� C ITY of UROloTO <br /> � '�i� �. %;;G�'� �, . Municipal Offices <br /> !h� .r_,./ � � . <br /> ` �,�� �� �r-i,�°' ',���G Street Address: °15a—a4q—�16� 0 Mailing Address: <br /> '`4k�Kpg' 2750 Kelley Parkway P.O. Box 66 <br /> - Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �0� `�'f�w`^ �, 'v � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-31: � <br /> 1 "CODE SYSTEM" An LSTS which meets all the location,design and construction standards of_the current Orono Municipal Code. _ <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipa!Code but does meet the tlu�ee foot separation requ'vemettt or rivo foot requirement for systems installed 1946 or earlier,and <br /> /''�which is not fiiling or an imminent threat to public health or safety. <br /> l 3 ,"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 1d0-year flood plain,any ISTS which may <br /> v or may not meet all the location,design,or construction standards of the cuaent Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than threE feet of unsaturated soil or sand betrveen the distribution�vice and the limiting soIl characteristics. <br /> TANK CONDITION(5-71: � <br /> T k inspection indicates: <br /> 5 1 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city oode recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped throuEh manhole and not through white inspection pipes. This allows for the proper <br /> cleanin� Keep water softner and iron filter discharge out of septic svstem to prolone life of drainfield. Ask aumper to test <br /> alarm float to verify alarm is still workin�in your house The alarm warns owner that septa�e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated eftluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �c A:c��-t\t� _ j S n 0 n- C�r•p\:a��' .�-- ,�v S fi �L <br /> 6��,�.<<� �7 \Z.,=J\ -Zao7 <br /> 6-\�-0'� ��"`°� �� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> No�e: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that dlis report does <br /> not �uarantee or certify that an existing system �vill continue tu function properly. but is mereiy an opinion of the adequacy of the system under current <br /> cunJitions based on the available ini'onnation. <br />