Laserfiche WebLink
Job N.ame:'ZB COMPANIES/WILLIAMS Truss ID: CX Q : 1 Drw : <br /> exc x-Loc REACT szzE tiE4�� TC 2x4 SPF #1/#2-CAN Web bracing required at each location shown. End verticals are designed for axial loads <br /> 1 0- 2-12 5ei 5.50�� 1.Sa�� BC 2x4 SPF C1650F1.SE � See standard details (TX01087001-001 revl). only unless noted otherwise. <br /> 2 le- 9- a 995 5.50�� 1.56^ 2x4 SPF #1/N2-CAN 8-9 **[PM]=PLATE MONITOR USED-See Joint Report** Extensions above or below the truss pro£ile <br /> BRG REQUZREMENTS shown are based ONLY WEB 2x3 SPF STUD-CAN Designed per ANSI/TPI 1-2002 (if any) have been designed for loads <br /> on the truss material at each bearing 2x4 SPF #1/N2-CAN 6-2, 9-5 Plating is based on quality control factors indicated only. Horizontal loads applied at <br /> 2x3 SPF #1/#2-CAN 7-4 Cq = 1.25 for wide face and the end of the extensions have not been <br /> Tc FORCE 1�ti. sem csi This design does not account for long term Cq = 1.25 £or narrow face. considered unless shown. A drop-leg to an <br /> i-2 175 0.04 0.71 0.75 time dependent loading (creep) . Building Any alterations to this are shown for otherwise unsupported wall may create a <br /> 2-3 -1306 0.02 0.71 0.7G Designer must account for this. individual joints on the Joint Report. hinge effect that requires additional design <br /> 3-4 -1177 0.01 0.71 0.73 THIS DESIGN IS THE COMPOSITE RESULT OF Re£er to Joint QC Detail Sheet for consideration (by others) . <br /> 4-5 -171 0.00 0.71 0.71 MULTZPLE LOAD CASES. Maximum Rotational Tolerance used UPLIFT REACTION(S) . <br /> Loaded for 10 PSF non-concurrent HCLL. IRC/IBC truss plate values are based on Support Main Wind Non-Wind <br /> ac FORCE r�cL sxo csi Shim bearings (if needed) £or req. support. testing and approval as required by IBC 1703 1 -49 lb <br /> 6-7 1241 0.09 0.71 0.90 HORIZONTAL REACTION(S) : and ANSI/TPI and are reported in available 2 -217 lb <br /> 7-8 743 O.oa o.71 0.75 support 1 413 lb documents as ER-1607 and ESR-1118. This truss is designed using the <br /> 8-9 790 0.07 0.50 0.57 support 2 413 lb ASCE7-OS Wind Speci£ication <br /> Bldg Enclosed = Yes, Importance Factor = 1.00 <br /> WEB FORCE CSI WEB FORCE CSI Truss Location = Not End Zone <br /> 1-6 -224 0.07 4-7 577 0.20 Hurricane/Ocean Line = No , Exp Category = B <br /> 2-6 -1561 0.55 4-9 -857 0.63 Bldg Length = 99.99 ft, Bldg Width = 50.00 ft <br /> 2-7 -236 0.13 5-9 -226 0.25 Mean roof height = 16.16 ft, mph = 90 <br /> ASCE7 II Standard Occupancy, Dead Load = 10.2 psf <br /> Designed as Main Wind Force Resisting Systesn <br /> - Low-rise and Components and Cladding <br /> Tributary Area = 38 sqft <br /> MP.X DEFLECTION (span) : <br /> 6-4-0 6-4-0 6-4-0 L/999 MEM 6-7 (LIVE) LC 25 <br /> 6-4-0 12-8-0 19-0-0 t.= -0.21" D= -0.21" T= -0.42 <br /> 1 2 3 4 5 Joint Locations --- <br /> 1 0- 0- 0 6 0- 0- 0 <br /> 2 6- 4- 0 7 9- 6- 0 <br /> 8•00 3 9- 2- 5 8 11- 3-13 <br /> 3X6 4 12- 8- 0 9 19- 0- 0 <br /> � 5 19- 0- 0 <br /> 3X4 83-9 <br /> S=4X6 <br /> 14-5-12 6X6 14-5-12 <br /> SHIP <br /> W:508 6X6 <br /> R:995 6-2-3 <br /> 2X3 3X4 U:-217 <br /> I,_9_,2 S-4Xs 1 <br /> 81 <br /> W:508 4X8 <br /> R:981 q.�U I <br /> U:-49 <br /> 0-5H 8 <br /> 19-0-0 <br /> 6 9-6-0 7 8 9-6-0 9 18-7-0 <br /> 9-6 0 19-0 0 STUB <br /> 9/29/2008 <br /> All connector plates are Truswal 20 ga.unless preceded by"W"for Wave 20 ga.,"HS"for HS 20 ga.,"S"for SS 18 ga.from Alpine;or preceded <br /> by"MX"for TWMX 20 ga.or"H"for 16 ga.from Truswal,positioned per Joint Detail Reports available from Truswal software,unless noted. Scale:3/32"=1' <br /> WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Wsnt: ��z WORK ORDER:208125 <br /> V I L LA U M E This design is for an individual building component not truss system It has been based on specifications provided by the component manufacturer Chk:MJK CUST:LAMPERT YARDS-A.V. <br /> and tlone in accordance with the current versions of TPI antl AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions <br /> are to be verified by the component manufacturer andlor building tlesigner prior to fabrication. The building tlesigner must ascertain that the loads Dsgnr:SJS DUE DATE:9/15/2008 <br /> utilizetl on this tlesign meet or exceetl the loatling imposed by the local building code antl the particular application.The design assumes that the top chord TC Live 35.00 psf DurFacs L=1.15 P=1.15 <br /> is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing matenal directly attached, unless otherwise <br /> noted. Bracing shown is for lateral support of components members only to reduce buckling length.This component shall not be placed in any TC Dead 7.00 PSf Defi.Ratio: 240 <br /> environment that will cause the moisture content of the wood to exceed 19%and/or cause connector plate corrosion. Fabricate,handle,install BC Live 0.00 psf O.C.Spacing 2-�-� <br /> 2926 Lone Oak Cifcle,St.Paul,MN 55121 and brace this truss in accordance with the follawing standards:'Joint and Cutting DeW il Reparts'available as output from Truswal software, <br /> PH;651-454-3610 FAX;651-454-4765 �ANSI/TPI 1','WTCA 1'-Wootl Truss Council of America Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION'- BC DBBd 10.00 psf Design Spec IRC-2006 <br /> (BCSI)and'BC51 SUMMARY SHEETS'by WTCA and TPI.The Truss Plate Institute(TPI)is located at 218 N.Lee Street Suite 312, <br /> Alexantlria,VA 22314.The American Fores[and Paper Association(AFPA)is located at 1111 19th Street,NW,Ste 800,Washington,DC 20036. TOTAL 52.00 psf Seqn T6.5.7 - 73962 <br />