�HVAE'-Residential HVAC Load Calculations Elite Software Development,Inc.
<br /> Flare Heating&A/C Inc. �' Schaefer Summer Ridge Rambler T.H.
<br /> ,' Golden Valley, MN 55427-3700 Page 2
<br /> - _ --- -- -- - _- -__ _ - --- -
<br /> - - - - ___ - -- -- -- - - - -
<br /> � Total Building Summary Loads �
<br /> _ - - - -- -- --- _ _ _ -- ---- -- -
<br /> Component Area Sen Lat Sen Total
<br /> ', � Description Quan _ Loss Gain Gain Gain '
<br /> I 4A Window Double Pane & Storm Clear Glass Wood Frame 302 9,474 0 7,260 7,260 i
<br /> 8M Glass Door pouble Clear Glass Wood Frame 102 5,171 0 3,060 3,060 ;
<br /> I 11C Door Metal Polystyrene Core 40 1,730 0 363 363
<br /> 121 Wall R-19 + 1/2"Asphit Board(R-1.3) 1721 8,708 0 2,233 2,233
<br /> 131 Part R-19 + 1/2"Asphlt Board(R-1.3) 275 1,392 0 226 226
<br /> , 15C Wall 2-5' Below Grade 8/12" BIk+R-11 112 526 0 0 0
<br /> '�, 15G Wall 5'or More Below Grade 8/12" BIk+R-11 496 1,962 0 0 0
<br /> ', 161 Ceiling R-44 Insulation 1650 3,491 0 1,670 1,670
<br /> i21A Basemt Floor 2' or More Below Grade 1593 3,517 0 0 0
<br /> Subtotals for structure: 35,971 0 14,812 14,812
<br /> People: 6 1,380 1,800 3,180
<br /> Equipment: 600 1,200 1,800 ,
<br /> ' Lighting: 0 0 0
<br /> Ductwork: 0 0 0 0 I
<br /> ' Infiltration: Winter CFM: 196, Summer CFM: 98 19,291 2,333 2,097 4,430
<br /> ', Ventilation: Winter CFM: 125, Summer CFM: 125 12,273 2,968 2,668 5,636
<br /> Sensible Gain Total: 22,577
<br /> , Temperature Swing Multiplier: X 1.00
<br /> ! Total Building Load Totals: 67,535 7,281 22,577 29,858
<br /> �
<br /> I ! Check Figures _� ��
<br /> Total Building Supply CFM: 933 CFM Per Square ft.: 0.293
<br /> Square ft. of Room Area: 3,186 Square ft. Per Ton: 1,280.446
<br /> i j Building Loads __�
<br /> i Total Heating Required With Outside Air: 67,535 Btuh 67.535 MBH
<br /> � Total Sensible Gain: 22,577 Btuh 76 °/o
<br /> 'i Total Latent Gain: 7,281 Btuh 24 °/o
<br /> � Total Cooling Required With Outside Air. 29,858 Btuh 2.488 Tons (Based On Sensible + Latent)
<br /> I 2.509 Tons (Based On 75% Sensible Capacity)
<br /> ; Notes
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> ' All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.
<br /> I
<br /> �
<br /> S:\FHDATA\PROJECTS\Z&B\summer ridge ramb th schaefer 745 bridgewater orono.rhv Monday, June 21, 2010, 2:35 PM