Laserfiche WebLink
RHVAC-Residential HVAC Load Calculations <br /> , Ffare Heating&AiC Inc �. Elite Software Development, Inc. <br /> i Gofden Valley, MN 55427-37�0 Summer Ridge Rambler Twin Home <br /> �t`Of E?'Ct f��3�01"� Page 1 <br /> '� General Project Information <br /> Project Filename: <br /> S:IFHDATAIPROJECTSIZ&Blsummer ridge rambter twin home mode! stonebay orono.rhv <br /> Project Title: Summer Ridge Rambler Twin Home <br /> Designed By: Randy <br /> Project Date: 11-14-07 <br /> Project Comment: Stonebay of Orono <br /> Client Name: ZB Companies, Inc. <br /> Client Address: 2670 Kelley parkway, #115 <br /> Client City: Orono, Minnesota 55356 <br /> Client Phone: 952-476-0032 <br /> Client Fax: 952-476-2203 <br /> Client Comment: <br /> Company Name: Flare Heating &Air conditioning, Inc. <br /> Company Representative� Randy <br /> , Company Address: 9303 Plymouth Ave. N. <br /> Company City: Golden Valley, Minnesota 55427 <br /> Company Phone: 763-542-1166 <br /> Company Fax: 763-542-3101 <br /> ! Company E-Mail Address: rimker@flareheating.com <br /> Company Website: flareheating.com <br /> Company Comment: You Can Feel The Difference <br /> __. <br /> Design Data _ _ <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Elevation Heating Adj, Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Outdoor Outdoor indoor Indoor Grains <br /> DrV Bulb Wet Bulb Ref.Hum Drv Bulb Difference <br /> Winter: _2p p 0 �2 � <br /> Summer: 95 75 50 75 36 <br /> __ _ __ <br /> ', Check Figures ___ __ _ __ <br /> Total Building Supply CFM: 945 CFM Per Square ft.: p 288 I <br /> Square ft. of Room Area: 3,280 Square ft. Per Ton: 1,294.169 <br /> I Building Loads __ _ . _ _ <br /> Total Heating Required With Outside Air: 67,205 Btuh 67.205 MBH <br /> Total Sensible Gain: 22,833 Btuh 75 % <br /> Total Latent Gain: 7,580 Btuh 25 % ' <br /> Total Cooling Required With Outside Air: 30,413 Btuh 2.534 Tons (Based On Sensible + Latent) <br /> 2.537 Tons (Based On 75% Sensible Capacity) �, <br /> I Notes _ _ _ __ _ _ � <br /> ' Calculations are based on 7th edition of ACCA Manual J. ' <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> S:\FHDATA\PROJECTS\Z&B\summer ridge rambler twin home model stonebay ordlkiecfrt�sday, November 14, 2007, 2:24 PM <br />