Laserfiche WebLink
BUILDING LEAKAGE TEST Page 2 of 4 <br /> Date of Test: 5/24/2016 Test File: Untitled <br /> BUILDING LEAKAGE TEST <br /> Date of Test: 5/24/2016 Test File: Untitled <br /> Customer: Summit Construction Technician: Cory W <br /> 1380 Briar St Project Number: <br /> Orono, MN 55391 <br /> Building Address: 1380 Briar St <br /> Orono, MN 55391 <br /> Test Results <br /> 1. Airflow at 50 Pascals: 562 CFM50 <br /> (50 Pa = 0.2 w.c.) 1.60 ACH50 <br /> 2. Leakage Area: 30.9 in2 LBL ELA @ 4 Pa <br /> 3. Building Leakage Curve: Flow Coefficient (C) = 44.2 <br /> Exponent(n) = 0.650 {Assumed) <br /> 4. Test Settings: Test Standard: RESNET One-Point Test <br /> Test Mode: Depressurization <br /> 5. Accuracy Level Standard Level of Accuracy Test <br /> Infittration Estimates <br /> 1. Estimated Average Annual Infiltration Rate: 29.7 CFM <br /> 0.08 ACH <br /> 5.9 CFM per person <br /> (using bedrooms + 1) <br /> 2. Estimated Design Infiltration Rate: Winter: 35.9 CFM Summer: 19.8 CFM <br /> 0.10 AC H 0.06 AC H <br /> Cost Estimates <br /> 1. Estimated Cost of Air Leakage for Heating: <br /> 2. Estimated Cost of Air Leakage for Cooling: <br />