s y <br /> Page 2 of 6 Report No. 4285 <br /> anchor.After the adhesive is cured in Configuration C,a 5/a-inch-diameter Findings <br /> hole is drilfed with a standard rotary drill bitthrough the plastic plug in the IV.Findin s That ITW RamseURead Head E con S stem Ceramic 6 <br /> end of the steel sleeve.The 5/8-inch threaded rod is inserted through the 9 � p Y <br /> hole and attached to the opposite side of the wall with the metal plate and Epoxy Anchors described in this report comply with the 1991 Unitorm <br /> nut. Building Code, subject to the following conditions: <br /> 3. Miscellaneous:Acceptability is contingent on the following: 1. The anchors are installed in accordance with the manufacturer's <br /> instructions and this report. <br /> a.Approval by the design engineec 2. Anchors are installed in holes and substrates predrifled with a <br /> b.Installation under special inspection in accordance with Section II D carhide-tipped masonry drill manufactured within the range of <br /> of the code. the maximum and minimum drill-tip dimensions of ANSI Stand- <br /> c.Only seismic loads are imposed on anchors. . ard 694.12-1977 for the allowable values set forth in this report. <br /> 3. Special inspection in accordance with Section 11 D is provided for <br /> d.Eonfigurations A and C for seismic shear loads: • all anchor installations. <br /> (1)Allowable load is applicable only where in-place sheartests indicate 4. Calculations and details showing compliance with this repo�t <br /> a minimum mortar strength of 50 psi net. are suhmitted to the local building official tor approval. <br /> (2) Twenry-five percent of anchors are tested by a special inspector 5. Anchors are not used to support tire-resistive construction. <br /> using a calibrated-torque wrench set at a minimum torque of 60 foot 6. Anchors are not used to resist tension forces in ceiling or wall <br /> pounds.Steel sleeves for anchors in Configuration C are tested prior to installations except as noted in this report. <br /> installation of threaded rods. 7..Anchors are not subjected to vi6ratory or shock loads, such as <br /> (3)Anchors installed in accordance with Configuration A and C have a supports for reciprocating engines or crane rails. <br /> minimum edge distance and spacing of 16 inches. 8. Adhesive anchors in unreinforced brick walls resist seismic <br /> e.Configuration B for seismic tension loads: forces only. <br /> (1)Allowable load is applicable only where in-place mortar shear tests i 99z Supplement to the U.B.C.:This report is unaffected by the supple- <br /> indicate a minimum ultimate strength of 50 psi net. ment. <br /> This report is subject to re-examination in two years. <br /> (2) Five percent of ancho�s are tested with a minimum of two tests <br /> required.Where the wall thickness varies,at least one test is performed <br /> on an anchorwhich hasthe leastembedment.Tests indicate that bolts can TABLE NO.1—MANUFACTURER'S RECOMMENDED CURE TIME <br /> sustain a tensile load of 3,000 pounds for a five-minute period with an FOR EPCON EPDXY ANCHORS <br /> allowable 10 percent deviation. M�N�nnuM coNCREre <br /> TEMPEflATURE(°F.) �NfT1AL SET TIME�(Hours) CURE TIMEz(Hours) <br /> Tests are unde�the supervision of the project engineer or an approved � 3.o as <br /> testing laboratory.As a minimum,the test report includes: 5o z.o 36 <br /> (aj Test location(s). bo �.s Za <br /> (b) Brick/mortar condition. sg �.o za <br /> (c) Bolt movemenUelongation. 90 �.0 2a <br /> (d� Embedme�t depth. zAnchors are to be undisturbed during the initial set time. <br /> Cure time required prior to application of allowable(desien)tensile and shear <br /> (e)Applied load. ioaas. . <br /> The pfOj2Ct ef)g1f188f dfld COf1t�3Ct01'R1USt SUbflllt th8 teSt f2pOft t0 thB TABLE NO.t{—REDUCTION FACTORS FOR REDUCED SPACING <br /> IOcal bUllding depaftment Wl�h d Stdtement Of COmpIldnCe With thlS fepOrt. AND EDGE DISTANCES FOR THREADED ROD INSTALLED IN <br /> (3)Twenty percent of installed anchors are tested by a special inspector CONCRETE WITH EPCON ADHESIVE�•2.3 <br /> using a torque-calibrated wrench to a minimum torque of 60 foot pounds. rer,s�or,cnPacm SHEAR CAPACITY <br /> (4)Configuration B anchors have a minimum edge distance and spac- Ed9`oi����m� F(F)f ea9 cDls ar�ice(m) Direcilon of Load F(F,>` <br /> ing of 16 inches. s –O.SOS 0.7 m –0.67m toward ed e 0.50 <br /> D. Special Inspection: Adhesive anchor installations require special m�° min– not toward age o.60 <br /> inspection in accordance with Section 306 of the code.The special inspec- ,,,,,,;,,-o.som o.� ,n,,,;„=o.so.» toward edge o.zs <br /> tor records the drill bit compliance with ANSI B94.12-1977; hole depth not[oward edge o.ao <br /> and cleanliness;product description,including product name,rod diame- s,„;,,=o.sos toward edae o.bo <br /> ter and length;adhesive expiration date;and verification of anchor instal- �o<<oWaTd edge i.00 � <br /> lation with the manufacturer'S pUbllShed if1StfUCti0f1S efld thiS fepOrt. �Linear iuterpolation is allowed for edge distances which fall between O.SOm, <br /> E.Identi(ication:The Epcon Ceramic 6 Epo�ry Anchors are identified by 0.67m and 1.00m,and anchor spacing which falls between O.SOS and 1.005. <br /> labels on the packaging indicating the manufacturer's name, product zLoad reduction factors should be combined where applicable.In the case where <br /> name, material type,serial number traceable to production date, length three or more anchors aze used,spacing reduction factors must be combined <br /> (multiplied). Where two or more edge distances affect perfortnance, edge <br /> dfld dI2fT12t8f Of thB thfB8d8d fOd. reduction factors mus[be combined.When a group of anchors is affected by <br /> both reduced spacing and reduced edge distances,the edge and spacing reduc- <br /> III. Evidence Submitted: Descriptive details and results of tension, tion factors must be combined. <br /> Sh@2f 2fld CfeBp 1eStS. jSee Figure No.2 for design example. <br />