My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011140
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road
>
4375 Bayside Road - 06-117-23-12-0009 - New PID
>
4375 Bayside Rd - PID: 06-117-23-12-0008 - Old PID
>
Permits/Inspections
>
1999-011140
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:23:11 PM
Creation date
1/19/2016 2:06:03 PM
Metadata
Fields
Template:
x Address Old
House Number
4375
Street Name
Bayside
Street Type
Road
Address
4375 Bayside Rd
Document Type
Permits/Inspections
PIN
0611723120009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' <br /> ' whitehurdwdwschd Heat loss <br /> ' Client Name: White <br /> Site Address: Orono, MN <br /> KEITH WATERS & ASSOCIATES, IN . <br /> 10340 Viking Drive Eden Prairie,MN 55344 License#000150 <br /> - Phone(612)942-1060 Fax(612)942-1058 <br /> Permitted Heat Loss <br /> Area(S . Ft.) x U Value = Heat Loss <br /> 1 Total exposed wall area: 575.40 0.11 393.29 <br /> 2 Total roof/ceiling area: 999.00 0.03 51.97 <br /> Total permitted heat loss: 445.27 <br /> Heat Loss Through Wall Segments <br /> Wall Windows 776.34 0.35 268.53 <br /> Doors 61.77 0.19 11.74 <br /> Rim Joist 336.60 0.04 13.16 <br /> Wall Framing(Average 10%) 240.07 0.11 25.84 <br /> Net Insulated Wall 160.62 0.04 89.54 <br /> Foundation Windows 0.00 0.00 0.00 <br /> Foundation Wall Above Grade 0.00 0.06 0.00 <br /> 3 Total heat loss through walls: 408.81 <br /> (If item#3 is the same as or less than item#1, <br /> then you have met the intent of SBC(c)2. <br /> Heat Loss Through Roof <br /> Skylight 0.00 0.34 0.00 <br /> Roof/Ceiling Framing(Average 10%) 199.90 0.03 5.69 <br /> Net Insulated Roof/Ceiling 799.10 0.02 29.12 <br /> 4 Total heat loss through roof: 34.81 <br /> (If item#4 is the same as or less than item#2, <br /> then you have met the intent of SBC(c)2. <br /> Alternate Building Envelope Design <br /> To utilize the total envelope system method,the values established by the sum of items#3 and#4 <br /> shall not be greater than the sum of items#1 and#2. <br /> Permitted Loss Item 1 + Item 2: 393.29 51.97 445.27 <br /> Actual Loss Item 3+Item 4: 408.81 34.81 443.62 <br /> Heat oss is acceptable <br /> 12/22/98 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.